Free and open · new CVEs checked every 20 minutesStatusRSSOpen dataContact

CVE-2006-5780: Stack-based buffer overflow in nfsd.exe in XLink Omni-NFS Server 5.2 allows remote attackers to execute arbitr

56
This week
HIGH 7.5DOWNGRADE

CVE-2006-5780 is a high-severity flaw (CVSS 7.5) affecting omni-nfs server. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

Stack-based buffer overflow in nfsd.exe in XLink Omni-NFS Server 5.2 allows remote attackers to execute arbitrary code via a crafted TCP packet to port 2049 (nfsd), as demonstrated by vd_xlink.pm.

Why this priority

  • High severity
  • EPSS top 1%: very likely to be exploited
  • Public exploit reference

No fix is published yet: follow the downgrade or mitigation steps.

Risk facts

CVSS score7.5 (High)
EPSS exploit chance63.4% (top 1%)
CISA exploited listNo
Published2006-11-07
Last modified2026-06-16
Publisher (CNA): MITRE · Vendor: xlink technology

Share: LinkedIn · X · Reddit

Last updated 2026-06-16 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

xlink technology omni-nfs server DOWNGRADE
Affected: 5.2
Fixed in: no fixed release known
Safe to downgrade to: a release before 5.2
1. Check installed version
apt-cache policy omni-nfs-server || rpm -q omni-nfs-server || omni-nfs-server --version
2. No fixed release: DOWNGRADE to a release before 5.2 (Debian / Ubuntu)
apt-cache madison omni-nfs-server sudo apt install omni-nfs-server=<VERSION_BEFORE_5.2> sudo apt-mark hold omni-nfs-server
2. No fixed release: DOWNGRADE (RHEL / Amazon Linux / Fedora)
dnf --showduplicates list omni-nfs-server sudo dnf downgrade omni-nfs-server-<VERSION_BEFORE_5.2> sudo dnf versionlock add omni-nfs-server
Downgrade risk
Downgrading can break dependent software and may reopen older bugs. Read the distro advisory first and test on a non-production host.
After downgrade
Restart the service, and keep the package held until a fixed release ships.

Public exploits and detection

Public code exists for this CVE. Treat unpatched systems as at risk, and only run PoCs in a lab.

Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2006-5780?

omni-nfs server: downgrade or apply the listed mitigation. Exact commands for each OS are on this page.

Is CVE-2006-5780 being exploited?

CVE-2006-5780 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2006-5780 affect?

CVE-2006-5780 affects omni-nfs server. Severity is high (CVSS 7.5). Stack-based buffer overflow in nfsd.exe in XLink Omni-NFS Server 5.2 allows remote attackers to execute arbitrary code via a crafted TCP packet to port 2049 (nfsd), as demonstrated by vd_xlink.pm.

How urgent is CVE-2006-5780?

Priority 56/100. High severity; EPSS top 1%: very likely to be exploited; Public exploit reference

References

← Back to latest CVEs

Get the weekly exploited-CVE digest by emailThe CVEs being attacked this week and how to fix them. No spam, unsubscribe any time.