CVE-2009-0216: GE Fanuc iFIX 5.0 and earlier relies on client-side authentication involving a weakly encrypted local password
CVE-2009-0216 is a high-severity flaw (CVSS 10.0) affecting ifix. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.
GE Fanuc iFIX 5.0 and earlier relies on client-side authentication involving a weakly encrypted local password file, which allows remote attackers to bypass intended access restrictions and start privileged server login sessions by recovering a password or by using a modified program module.
Why this priority
- Critical severity
A fixed release or distro patch exists.
Risk facts
| CVSS score | 10.0 (High) |
| EPSS exploit chance | 3.0% (top 13%) |
| CISA exploited list | No |
| Weakness | CWE-255 |
| Published | 2009-02-13 |
| Last modified | 2026-06-16 |
Last updated 2026-06-16 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score
Am I affected?
Timeline
- Published CVE record published
- Updated Record last modified
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.
Quick answers
How do I fix CVE-2009-0216?
ifix: upgrade to newer than 5.0. Exact commands for each OS are on this page.
Is CVE-2009-0216 being exploited?
CVE-2009-0216 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.
What does CVE-2009-0216 affect?
CVE-2009-0216 affects ifix. Severity is high (CVSS 10.0). GE Fanuc iFIX 5.0 and earlier relies on client-side authentication involving a weakly encrypted local password file, which allows remote attackers to bypass intended access restrictions and start privileged server login sessions by recoveri
How urgent is CVE-2009-0216?
Priority 57/100. Critical severity
Related CVEs
- CVE-2023-0598 HIGH 7.8 DOWNGRADE GE Digital Proficy iFIX 2022, GE Digital Proficy iFIX v6.1, and GE Digital Proficy iFIX v6.5 are vulnerable t
- CVE-2019-18255 MEDIUM 5.5 UPGRADE HMI/SCADA iFIX (Versions 6.1 and prior) allows a local authenticated user to modify system-wide iFIX configura
- CVE-2019-18243 MEDIUM 5.5 UPGRADE HMI/SCADA iFIX (Versions 6.1 and prior) allows a local authenticated user to modify system-wide iFIX configura
- CVE-2018-17925 MEDIUM 4.8 UPGRADE Multiple instances of this vulnerability (Unsafe ActiveX Control Marked Safe For Scripting) have been identifi
- CVE-2016-9360 MEDIUM 6.7 UPGRADE UPGRADE An issue was discovered in General Electric (GE) Proficy HMI/SCADA iFIX Version 5.8 SIM 13 and prior versions,