CVE-2010-5310: The Acquisition Workstation for the GE Healthcare Revolution XQ/i has a password of adw3.1 for the sdc user, w

54
This month
HIGH 10.0MITIGATE

CVE-2010-5310 is a high-severity flaw (CVSS 10.0) affecting revolution xq\/i. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

The Acquisition Workstation for the GE Healthcare Revolution XQ/i has a password of adw3.1 for the sdc user, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value.

Why this priority

  • Critical severity

No fix is published yet: follow the downgrade or mitigation steps.

Risk facts

CVSS score10.0 (High)
EPSS exploit chance1.7% (top 23%)
CISA exploited listNo
WeaknessCWE-255
Published2015-08-04
Last modified2026-06-16
Publisher (CNA): MITRE · Vendor: gehealthcare

Share: LinkedIn · X · Reddit

Last updated 2026-06-16 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

gehealthcare revolution xq\/i MITIGATE
Affected: all versions
Fixed in: no fixed release known
Safe to downgrade to: no unaffected older release
Firmware
Install the latest firmware from the vendor advisory; if none, apply the vendor workaround.
Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2010-5310?

revolution xq\/i: mitigate or apply the listed mitigation. Exact commands for each OS are on this page.

Is CVE-2010-5310 being exploited?

CVE-2010-5310 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2010-5310 affect?

CVE-2010-5310 affects revolution xq\/i. Severity is high (CVSS 10.0). The Acquisition Workstation for the GE Healthcare Revolution XQ/i has a password of adw3.1 for the sdc user, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent o

How urgent is CVE-2010-5310?

Priority 54/100. Critical severity