Free and open · new CVEs checked every 20 minutesStatusRSSOpen dataContact

CVE-2012-3815: Buffer overflow in RunTime.exe in Sielco Sistemi Winlog Pro SCADA before 2.07.18 and Winlog Lite SCADA before

62
This week
HIGH 9.3UPGRADEUPGRADE

CVE-2012-3815 is a high-severity flaw (CVSS 9.3) affecting winlog lite, winlog pro. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

Buffer overflow in RunTime.exe in Sielco Sistemi Winlog Pro SCADA before 2.07.18 and Winlog Lite SCADA before 2.07.18 allows remote attackers to execute arbitrary code via a crafted packet to TCP port 46824. NOTE: some of these details are obtained from third party information.

Why this priority

  • Critical severity
  • EPSS top 1%: very likely to be exploited
  • Public exploit reference

A fixed release or distro patch exists.

Risk facts

CVSS score9.3 (High)
EPSS exploit chance43.8% (top 1%)
CISA exploited listNo
WeaknessCWE-119
Published2012-06-27
Last modified2026-06-16
Publisher (CNA): MITRE · Vendor: sielcosistemi

Share: LinkedIn · X · Reddit

Last updated 2026-06-16 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

sielcosistemi winlog lite UPGRADE
Affected: <= 2.07.14 · 2.06.00 · 2.06.03 · 2.06.04 · 2.06.06 · 2.06.09 · 2.06.10 · 2.06.12
Fixed in: newer than 2.07.14
Safe to downgrade to: no unaffected older release
1. Check installed version
apt-cache policy winlog-lite || rpm -q winlog-lite || winlog-lite --version
2. UPGRADE to newer than 2.07.14 (Debian / Ubuntu)
sudo apt update && sudo apt install --only-upgrade winlog-lite
2. UPGRADE (RHEL / Amazon Linux / Fedora)
sudo dnf upgrade winlog-lite
Note
Distros often backport fixes without changing the version number. Confirm with the distro advisory or changelog.
sielcosistemi winlog pro UPGRADE
Affected: <= 2.07.14 · 2.06.00 · 2.06.03 · 2.06.04 · 2.06.06 · 2.06.09 · 2.06.10 · 2.06.12
Fixed in: newer than 2.07.14
Safe to downgrade to: no unaffected older release
1. Check installed version
apt-cache policy winlog-pro || rpm -q winlog-pro || winlog-pro --version
2. UPGRADE to newer than 2.07.14 (Debian / Ubuntu)
sudo apt update && sudo apt install --only-upgrade winlog-pro
2. UPGRADE (RHEL / Amazon Linux / Fedora)
sudo dnf upgrade winlog-pro
Note
Distros often backport fixes without changing the version number. Confirm with the distro advisory or changelog.

Public exploits and detection

Public code exists for this CVE. Treat unpatched systems as at risk, and only run PoCs in a lab.

Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2012-3815?

winlog lite: upgrade to newer than 2.07.14; winlog pro: upgrade to newer than 2.07.14. Exact commands for each OS are on this page.

Is CVE-2012-3815 being exploited?

CVE-2012-3815 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2012-3815 affect?

CVE-2012-3815 affects winlog lite, winlog pro. Severity is high (CVSS 9.3). Buffer overflow in RunTime.exe in Sielco Sistemi Winlog Pro SCADA before 2.07.18 and Winlog Lite SCADA before 2.07.18 allows remote attackers to execute arbitrary code via a crafted packet to TCP port 46824. NOTE: some of these details are

How urgent is CVE-2012-3815?

Priority 62/100. Critical severity; EPSS top 1%: very likely to be exploited; Public exploit reference

Related CVEs

References

← Back to latest CVEs

Get the weekly exploited-CVE digest by emailThe CVEs being attacked this week and how to fix them. No spam, unsubscribe any time.