CVE-2012-4353: Stack-based buffer overflow in RunTime.exe in Sielco Sistemi Winlog Pro SCADA before 2.07.17 and Winlog Lite S
CVE-2012-4353 is a high-severity flaw (CVSS 9.3) affecting winlog pro, winlog lite. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.
Stack-based buffer overflow in RunTime.exe in Sielco Sistemi Winlog Pro SCADA before 2.07.17 and Winlog Lite SCADA before 2.07.17 allows remote attackers to execute arbitrary code via a crafted port-46824 TCP packet that triggers an incorrect file-open attempt by the _TCPIPS_BinOpenFileFP function, a different vulnerability than CVE-2012-3815. NOTE: some of these details are obtained from third party information.
Why this priority
- Critical severity
- EPSS top 2%: very likely to be exploited
- Public exploit reference
A fixed release or distro patch exists.
Risk facts
| CVSS score | 9.3 (High) |
| EPSS exploit chance | 24.7% (top 2%) |
| CISA exploited list | No |
| Weakness | CWE-119 |
| Published | 2012-08-19 |
| Last modified | 2026-06-16 |
Last updated 2026-06-16 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score
Am I affected?
Timeline
- Published CVE record published
- Updated Record last modified
Public exploits and detection
Public code exists for this CVE. Treat unpatched systems as at risk, and only run PoCs in a lab.
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.
Quick answers
How do I fix CVE-2012-4353?
winlog pro: upgrade to newer than 2.07.16; winlog lite: upgrade to newer than 2.07.16. Exact commands for each OS are on this page.
Is CVE-2012-4353 being exploited?
CVE-2012-4353 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.
What does CVE-2012-4353 affect?
CVE-2012-4353 affects winlog pro, winlog lite. Severity is high (CVSS 9.3). Stack-based buffer overflow in RunTime.exe in Sielco Sistemi Winlog Pro SCADA before 2.07.17 and Winlog Lite SCADA before 2.07.17 allows remote attackers to execute arbitrary code via a crafted port-46824 TCP packet that triggers an incorre
How urgent is CVE-2012-4353?
Priority 62/100. Critical severity; EPSS top 2%: very likely to be exploited; Public exploit reference
Related CVEs
- CVE-2017-5161 HIGH 7.2 UPGRADE UPGRADE An issue was discovered in Sielco Sistemi Winlog Lite SCADA Software, versions prior to Version 3.02.01, and W
- CVE-2012-4359 HIGH 9.3 UPGRADE UPGRADE Sielco Sistemi Winlog Pro SCADA before 2.07.18 and Winlog Lite SCADA before 2.07.18 do not validate the return
- CVE-2012-4358 HIGH 9.3 UPGRADE UPGRADE Sielco Sistemi Winlog Pro SCADA before 2.07.17 and Winlog Lite SCADA before 2.07.17 do not validate the return
- CVE-2012-4357 HIGH 9.3 UPGRADE UPGRADE Array index error in Sielco Sistemi Winlog Pro SCADA before 2.07.17 and Winlog Lite SCADA before 2.07.17 might
- CVE-2012-4356 MEDIUM 4.3 UPGRADE UPGRADE Multiple directory traversal vulnerabilities in Sielco Sistemi Winlog Pro SCADA before 2.07.17 and Winlog Lite