CVE-2012-4354: TCPIPS_Story.dll in Sielco Sistemi Winlog Pro SCADA before 2.07.17 and Winlog Lite SCADA before 2.07.17 allows
CVE-2012-4354 is a high-severity flaw (CVSS 9.3) affecting winlog pro, winlog lite. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.
TCPIPS_Story.dll in Sielco Sistemi Winlog Pro SCADA before 2.07.17 and Winlog Lite SCADA before 2.07.17 allows remote attackers to execute arbitrary code via a port-46824 TCP packet with a crafted positive integer after the opcode, triggering incorrect function-pointer processing that can lead to a buffer overflow. NOTE: some of these details are obtained from third party information.
Why this priority
- Critical severity
- EPSS top 5%: very likely to be exploited
- Public exploit reference
A fixed release or distro patch exists.
Risk facts
| CVSS score | 9.3 (High) |
| EPSS exploit chance | 8.2% (top 5%) |
| CISA exploited list | No |
| Weakness | CWE-189 |
| Published | 2012-08-19 |
| Last modified | 2026-06-16 |
Last updated 2026-06-16 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score
Am I affected?
Timeline
- Published CVE record published
- Updated Record last modified
Public exploits and detection
Public code exists for this CVE. Treat unpatched systems as at risk, and only run PoCs in a lab.
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.
Quick answers
How do I fix CVE-2012-4354?
winlog pro: upgrade to newer than 2.07.16; winlog lite: upgrade to newer than 2.07.16. Exact commands for each OS are on this page.
Is CVE-2012-4354 being exploited?
CVE-2012-4354 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.
What does CVE-2012-4354 affect?
CVE-2012-4354 affects winlog pro, winlog lite. Severity is high (CVSS 9.3). TCPIPS_Story.dll in Sielco Sistemi Winlog Pro SCADA before 2.07.17 and Winlog Lite SCADA before 2.07.17 allows remote attackers to execute arbitrary code via a port-46824 TCP packet with a crafted positive integer after the opcode, triggeri
How urgent is CVE-2012-4354?
Priority 61/100. Critical severity; EPSS top 5%: very likely to be exploited; Public exploit reference
Related CVEs
- CVE-2017-5161 HIGH 7.2 UPGRADE UPGRADE An issue was discovered in Sielco Sistemi Winlog Lite SCADA Software, versions prior to Version 3.02.01, and W
- CVE-2012-4359 HIGH 9.3 UPGRADE UPGRADE Sielco Sistemi Winlog Pro SCADA before 2.07.18 and Winlog Lite SCADA before 2.07.18 do not validate the return
- CVE-2012-4358 HIGH 9.3 UPGRADE UPGRADE Sielco Sistemi Winlog Pro SCADA before 2.07.17 and Winlog Lite SCADA before 2.07.17 do not validate the return
- CVE-2012-4357 HIGH 9.3 UPGRADE UPGRADE Array index error in Sielco Sistemi Winlog Pro SCADA before 2.07.17 and Winlog Lite SCADA before 2.07.17 might
- CVE-2012-4356 MEDIUM 4.3 UPGRADE UPGRADE Multiple directory traversal vulnerabilities in Sielco Sistemi Winlog Pro SCADA before 2.07.17 and Winlog Lite