Free and open · new CVEs checked every 20 minutesStatusRSSOpen dataContact

CVE-2013-0687: The installer routine in Schneider Electric MiCOM S1 Studio uses world-writable permissions for executable fil

30
Routine
MEDIUM 6.6MITIGATE

CVE-2013-0687 is a medium-severity flaw (CVSS 6.6) affecting micom s1 studio. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

The installer routine in Schneider Electric MiCOM S1 Studio uses world-writable permissions for executable files, which allows local users to modify the service or the configuration files, and consequently gain privileges or trigger incorrect protective-relay operation, via a Trojan horse executable file.

Why this priority

  • No elevated risk signals yet

No fix is published yet: follow the downgrade or mitigation steps.

Risk facts

CVSS score6.6 (Medium)
EPSS exploit chance0.3% (top 73%)
CISA exploited listNo
WeaknessCWE-264
Published2013-04-18
Last modified2026-06-16
Publisher (CNA): ICS-CERT · Vendor: schneider-electric

Share: LinkedIn · X · Reddit

Last updated 2026-06-16 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

schneider-electric micom s1 studio MITIGATE
Affected: all versions
Fixed in: no fixed release known
Safe to downgrade to: no unaffected older release
1. Check installed version
apt-cache policy micom-s1-studio || rpm -q micom-s1-studio || micom-s1-studio --version
No fixed or unaffected release known
Apply the vendor mitigation from the advisory, disable the affected feature, or restrict network access.
Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2013-0687?

micom s1 studio: mitigate or apply the listed mitigation. Exact commands for each OS are on this page.

Is CVE-2013-0687 being exploited?

CVE-2013-0687 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2013-0687 affect?

CVE-2013-0687 affects micom s1 studio. Severity is medium (CVSS 6.6). The installer routine in Schneider Electric MiCOM S1 Studio uses world-writable permissions for executable files, which allows local users to modify the service or the configuration files, and consequently gain privileges or trigger incorre

How urgent is CVE-2013-0687?

Priority 30/100. No elevated risk signals yet.

Software pages

Schneider Electric vulnerabilities

Related CVEs

References

← Back to latest CVEs

Get the weekly exploited-CVE digest by emailThe CVEs being attacked this week and how to fix them. No spam, unsubscribe any time.