CVE-2013-6884: The write-blocker in CRU Ditto Forensic FieldStation with firmware before 2013Oct15a has a default "ditto" use
CVE-2013-6884 is a high-severity flaw (CVSS 10.0) affecting ditto forensic fieldstation firmware, ditto forensic fieldstation. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.
The write-blocker in CRU Ditto Forensic FieldStation with firmware before 2013Oct15a has a default "ditto" username and password, which allows remote attackers to gain privileges.
Why this priority
- Critical severity
- EPSS top 4%: very likely to be exploited
- Public exploit reference
A fixed release or distro patch exists.
Risk facts
| CVSS score | 10.0 (High) |
| EPSS exploit chance | 10.3% (top 4%) |
| CISA exploited list | No |
| Weakness | CWE-255 |
| Published | 2014-01-07 |
| Last modified | 2026-06-17 |
Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score
Am I affected?
Timeline
- Published CVE record published
- Updated Record last modified
Public exploits and detection
Public code exists for this CVE. Treat unpatched systems as at risk, and only run PoCs in a lab.
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.
Quick answers
How do I fix CVE-2013-6884?
ditto forensic fieldstation firmware: upgrade to newer than 2013jun30a; ditto forensic fieldstation: mitigate or apply the listed mitigation. Exact commands for each OS are on this page.
Is CVE-2013-6884 being exploited?
CVE-2013-6884 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.
What does CVE-2013-6884 affect?
CVE-2013-6884 affects ditto forensic fieldstation firmware, ditto forensic fieldstation. Severity is high (CVSS 10.0). The write-blocker in CRU Ditto Forensic FieldStation with firmware before 2013Oct15a has a default "ditto" username and password, which allows remote attackers to gain privileges.
How urgent is CVE-2013-6884?
Priority 64/100. Critical severity; EPSS top 4%: very likely to be exploited; Public exploit reference
Related CVEs
- CVE-2013-6883 MEDIUM 6.8 UPGRADE MITIGATE Cross-site request forgery (CSRF) vulnerability in CRU Ditto Forensic FieldStation with firmware before 2013Oc
- CVE-2013-6882 MEDIUM 4.3 UPGRADE MITIGATE Multiple cross-site scripting (XSS) vulnerabilities in CRU Ditto Forensic FieldStation with firmware 2013Oct15
- CVE-2013-6881 HIGH 10.0 UPGRADE MITIGATE CRU Ditto Forensic FieldStation with firmware before 2013Oct15a allows remote attackers to execute arbitrary c