CVE-2017-12069: An XXE vulnerability has been identified in OPC Foundation UA .NET Sample Code before 2017-03-21 and Local Dis
CVE-2017-12069 is a high-severity flaw (CVSS 8.2) affecting simatic pcs7, wincc, local discovery server. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.
An XXE vulnerability has been identified in OPC Foundation UA .NET Sample Code before 2017-03-21 and Local Discovery Server (LDS) before 1.03.367. Among the affected products are Siemens SIMATIC PCS7 (All versions V8.1 and earlier), SIMATIC WinCC (All versions < V7.4 SP1), SIMATIC WinCC Runtime Professional (All versions < V14 SP1), SIMATIC NET PC Software, and SIMATIC IT Production Suite. By sending specially crafted packets to the OPC Discovery
Why this priority
- High severity
- Remotely exploitable, no login, no user action
A fixed release or distro patch exists.
Risk facts
| CVSS score | 8.2 (High) |
| Attack vector | Network (remote) |
| Attack complexity | Low |
| Privileges needed | None |
| User interaction | None |
| EPSS exploit chance | 2.9% (top 13%) |
| CISA exploited list | No |
| Weakness | CWE-611 |
| Published | 2017-08-30 |
| Last modified | 2026-06-17 |
Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score
Am I affected?
Timeline
- Published CVE record published
- Updated Record last modified
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.
Quick answers
How do I fix CVE-2017-12069?
simatic pcs7: upgrade to newer than 8.1; wincc: upgrade to newer than 7.4; local discovery server: upgrade to newer than 1.01.333.0. Exact commands for each OS are on this page.
Is CVE-2017-12069 being exploited?
CVE-2017-12069 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.
What does CVE-2017-12069 affect?
CVE-2017-12069 affects simatic pcs7, wincc, local discovery server. Severity is high (CVSS 8.2). An XXE vulnerability has been identified in OPC Foundation UA .NET Sample Code before 2017-03-21 and Local Discovery Server (LDS) before 1.03.367. Among the affected products are Siemens SIMATIC PCS7 (All versions V8.1 and earlier), SIMATIC
How urgent is CVE-2017-12069?
Priority 55/100. High severity; Remotely exploitable, no login, no user action
Software pages
Related CVEs
- CVE-2017-14023 MEDIUM 4.9 DOWNGRADE DOWNGRADE An Improper Input Validation issue was discovered in Siemens SIMATIC PCS 7 V8.1 prior to V8.1 SP1 with WinCC V
- CVE-2016-7165 MEDIUM 6.4 MITIGATE MITIGATE A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC IT Producti
- CVE-2014-8552 MEDIUM 5.0 DOWNGRADE DOWNGRADE The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMAT
- CVE-2014-8551 HIGH 10.0 DOWNGRADE DOWNGRADE The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMAT
- CVE-2014-4686 MEDIUM 6.8 UPGRADE UPGRADE The Project administration application in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products