Free and open · new CVEs checked every 20 minutesStatusRSSOpen dataContact

CVE-2017-12718: A Classic Buffer Overflow issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump

62
This week
HIGH 8.1REMOTEMITIGATE

CVE-2017-12718 is a high-severity flaw (CVSS 8.1) affecting medfusion 4000 wireless syringe infusion pump. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

A Classic Buffer Overflow issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on the target device. The pump receives the potentially malicious input infrequently and under certain conditions, increasing the difficulty of exploitation.

Why this priority

  • High severity
  • EPSS top 4%: very likely to be exploited
  • Public exploit reference
  • Remotely exploitable, no login, no user action

No fix is published yet: follow the downgrade or mitigation steps.

Risk facts

CVSS score8.1 (High)
Attack vectorNetwork (remote)
Attack complexityHigh
Privileges neededNone
User interactionNone
EPSS exploit chance12.8% (top 4%)
CISA exploited listNo
WeaknessCWE-120, CWE-119
Published2018-02-15
Last modified2026-06-17
Publisher (CNA): ICS-CERT · Vendor: smiths-medical

Share: LinkedIn · X · Reddit

Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

smiths-medical medfusion 4000 wireless syringe infusion pump MITIGATE
Affected: 1.1 · 1.5 · 1.6
Fixed in: no fixed release known
Safe to downgrade to: a release before 1.1
Check your OS release
cat /etc/os-release; uname -r
Debian / Ubuntu
sudo apt update && sudo apt full-upgrade
RHEL / Amazon Linux / Fedora
sudo dnf upgrade --refresh
Windows
Install the latest cumulative update from Windows Update
If no patch exists yet
OS downgrades are not safe. Apply the vendor mitigation from the advisory and restrict exposure.

Public exploits and detection

Public code exists for this CVE. Treat unpatched systems as at risk, and only run PoCs in a lab.

Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2017-12718?

medfusion 4000 wireless syringe infusion pump: mitigate or apply the listed mitigation. Exact commands for each OS are on this page.

Is CVE-2017-12718 being exploited?

CVE-2017-12718 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2017-12718 affect?

CVE-2017-12718 affects medfusion 4000 wireless syringe infusion pump. Severity is high (CVSS 8.1). A Classic Buffer Overflow issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump does not verify input buffer size prior to copying, leading

How urgent is CVE-2017-12718?

Priority 62/100. High severity; EPSS top 4%: very likely to be exploited; Public exploit reference; Remotely exploitable, no login, no user action

Related CVEs

References

← Back to latest CVEs

Get the weekly exploited-CVE digest by emailThe CVEs being attacked this week and how to fix them. No spam, unsubscribe any time.