Free and open · new CVEs checked every 20 minutesStatusRSSOpen dataContact

CVE-2017-17867: Inteno iopsys 2.0-3.14 and 4.0 devices allow remote authenticated users to execute arbitrary OS commands by mo

60
This week
HIGH 8.8UPGRADE

CVE-2017-17867 is a high-severity flaw (CVSS 8.8) affecting iopsys. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

Inteno iopsys 2.0-3.14 and 4.0 devices allow remote authenticated users to execute arbitrary OS commands by modifying the leasetrigger field in the odhcpd configuration to specify an arbitrary program, as demonstrated by a program located on an SMB share. This issue existed because the /etc/uci-defaults directory was not being used to secure the OpenWrt configuration.

Why this priority

  • High severity
  • EPSS top 4%: very likely to be exploited
  • Public exploit reference

A fixed release or distro patch exists.

Risk facts

CVSS score8.8 (High)
Attack vectorNetwork (remote)
Attack complexityLow
Privileges neededLow
User interactionNone
EPSS exploit chance11.1% (top 4%)
CISA exploited listNo
WeaknessCWE-732
Published2018-01-04
Last modified2026-06-17
Publisher (CNA): MITRE · Vendor: intenogroup

Share: LinkedIn · X · Reddit

Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

intenogroup iopsys UPGRADE
Affected: >= 2.0 and <= 3.14 · 4.0
Fixed in: newer than 3.14
Safe to downgrade to: a release before 2.0
Firmware
Install the latest firmware from the vendor advisory; if none, apply the vendor workaround.

Public exploits and detection

Public code exists for this CVE. Treat unpatched systems as at risk, and only run PoCs in a lab.

Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2017-17867?

iopsys: upgrade to newer than 3.14. Exact commands for each OS are on this page.

Is CVE-2017-17867 being exploited?

CVE-2017-17867 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2017-17867 affect?

CVE-2017-17867 affects iopsys. Severity is high (CVSS 8.8). Inteno iopsys 2.0-3.14 and 4.0 devices allow remote authenticated users to execute arbitrary OS commands by modifying the leasetrigger field in the odhcpd configuration to specify an arbitrary program, as demonstrated by a program located o

How urgent is CVE-2017-17867?

Priority 60/100. High severity; EPSS top 4%: very likely to be exploited; Public exploit reference

Software pages

OpenWrt vulnerabilities

Related CVEs

References

← Back to latest CVEs

Get the weekly exploited-CVE digest by emailThe CVEs being attacked this week and how to fix them. No spam, unsubscribe any time.