Free and open · new CVEs checked every 20 minutesStatusRSSOpen dataContact

CVE-2017-3185: ACTi cameras including the D, B, I, and E series using firmware version A1D-500-V6.11.31-AC have a web applica

61
This week
CRITICAL 9.8REMOTEMITIGATE

CVE-2017-3185 is a critical-severity flaw (CVSS 9.8) affecting camera firmware. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

ACTi cameras including the D, B, I, and E series using firmware version A1D-500-V6.11.31-AC have a web application that uses the GET method to process requests that contain sensitive information such as user account name and password, which can expose that information through the browser's history, referrers, web logs, and other sources.

Why this priority

  • Critical severity
  • Remotely exploitable, no login, no user action

No fix is published yet: follow the downgrade or mitigation steps.

Risk facts

CVSS score9.8 (Critical)
Attack vectorNetwork (remote)
Attack complexityLow
Privileges neededNone
User interactionNone
EPSS exploit chance3.2% (top 12%)
CISA exploited listNo
WeaknessCWE-598, CWE-200
Published2017-12-16
Last modified2026-06-17
Publisher (CNA): CERT/CC · Vendor: acti

Share: LinkedIn · X · Reddit

Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

acti camera firmware MITIGATE
Affected: a1d-500-v6.11.31-ac
Fixed in: no fixed release known
Safe to downgrade to: a release before a1d-500-v6.11.31-ac
Check your OS release
cat /etc/os-release; uname -r
Debian / Ubuntu
sudo apt update && sudo apt full-upgrade
RHEL / Amazon Linux / Fedora
sudo dnf upgrade --refresh
Windows
Install the latest cumulative update from Windows Update
If no patch exists yet
OS downgrades are not safe. Apply the vendor mitigation from the advisory and restrict exposure.
Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2017-3185?

camera firmware: mitigate or apply the listed mitigation. Exact commands for each OS are on this page.

Is CVE-2017-3185 being exploited?

CVE-2017-3185 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2017-3185 affect?

CVE-2017-3185 affects camera firmware. Severity is critical (CVSS 9.8). ACTi cameras including the D, B, I, and E series using firmware version A1D-500-V6.11.31-AC have a web application that uses the GET method to process requests that contain sensitive information such as user account name and password, which

How urgent is CVE-2017-3185?

Priority 61/100. Critical severity; Remotely exploitable, no login, no user action

Related CVEs

References

← Back to latest CVEs

Get the weekly exploited-CVE digest by emailThe CVEs being attacked this week and how to fix them. No spam, unsubscribe any time.