Free and open · new CVEs checked every 20 minutesStatusRSSOpen dataContact

CVE-2017-5177: A Stack Buffer Overflow issue was discovered in VIPA Controls WinPLC7 5.0.45.5921 and prior

61
This week
HIGH 7.5REMOTEUPGRADE

CVE-2017-5177 is a high-severity flaw (CVSS 7.5) affecting winplc7 firmware. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

A Stack Buffer Overflow issue was discovered in VIPA Controls WinPLC7 5.0.45.5921 and prior. A stack-based buffer overflow vulnerability has been identified, where an attacker with a specially crafted packet could overflow the fixed length buffer. This could allow remote code execution.

Why this priority

  • High severity
  • EPSS top 3%: very likely to be exploited
  • Public exploit reference
  • Remotely exploitable, no login, no user action

A fixed release or distro patch exists.

Risk facts

CVSS score7.5 (High)
Attack vectorNetwork (remote)
Attack complexityLow
Privileges neededNone
User interactionNone
EPSS exploit chance17.7% (top 3%)
CISA exploited listNo
WeaknessCWE-121, CWE-119
Published2017-05-19
Last modified2026-06-17
Publisher (CNA): ICS-CERT · Vendor: vipa controls

Share: LinkedIn · X · Reddit

Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

vipa controls winplc7 firmware UPGRADE
Affected: <= 5.0.45.5921
Fixed in: newer than 5.0.45.5921
Safe to downgrade to: no unaffected older release
Check your OS release
cat /etc/os-release; uname -r
Debian / Ubuntu
sudo apt update && sudo apt full-upgrade
RHEL / Amazon Linux / Fedora
sudo dnf upgrade --refresh
Windows
Install the latest cumulative update from Windows Update
If no patch exists yet
OS downgrades are not safe. Apply the vendor mitigation from the advisory and restrict exposure.

Public exploits and detection

Public code exists for this CVE. Treat unpatched systems as at risk, and only run PoCs in a lab.

Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2017-5177?

winplc7 firmware: upgrade to newer than 5.0.45.5921. Exact commands for each OS are on this page.

Is CVE-2017-5177 being exploited?

CVE-2017-5177 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2017-5177 affect?

CVE-2017-5177 affects winplc7 firmware. Severity is high (CVSS 7.5). A Stack Buffer Overflow issue was discovered in VIPA Controls WinPLC7 5.0.45.5921 and prior. A stack-based buffer overflow vulnerability has been identified, where an attacker with a specially crafted packet could overflow the fixed length

How urgent is CVE-2017-5177?

Priority 61/100. High severity; EPSS top 3%: very likely to be exploited; Public exploit reference; Remotely exploitable, no login, no user action

References

← Back to latest CVEs

Get the weekly exploited-CVE digest by emailThe CVEs being attacked this week and how to fix them. No spam, unsubscribe any time.