Free and open · new CVEs checked every 20 minutesStatusRSSOpen dataContact

CVE-2018-13989: Grundig Smart Inter@ctive TV 3.0 devices allow CSRF attacks via a POST request to TCP port 8085 containing a p

56
This month
HIGH 8.8MITIGATE

CVE-2018-13989 is a high-severity flaw (CVSS 8.8) affecting grundig smart inter\@ctive firmware. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

Grundig Smart Inter@ctive TV 3.0 devices allow CSRF attacks via a POST request to TCP port 8085 containing a predictable ID value, as demonstrated by a /sendrcpackage?keyid=-2544&keysymbol=-4081 request to shut off the device.

Why this priority

  • High severity
  • Public exploit reference

No fix is published yet: follow the downgrade or mitigation steps.

Risk facts

CVSS score8.8 (High)
Attack vectorNetwork (remote)
Attack complexityLow
Privileges neededNone
User interactionRequired
EPSS exploit chance2.0% (top 19%)
CISA exploited listNo
WeaknessCWE-352
Published2018-07-11
Last modified2026-06-17
Publisher (CNA): MITRE · Vendor: arcelikas

Share: LinkedIn · X · Reddit

Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

arcelikas grundig smart inter\@ctive firmware MITIGATE
Affected: 3.0
Fixed in: no fixed release known
Safe to downgrade to: a release before 3.0
Check your OS release
cat /etc/os-release; uname -r
Debian / Ubuntu
sudo apt update && sudo apt full-upgrade
RHEL / Amazon Linux / Fedora
sudo dnf upgrade --refresh
Windows
Install the latest cumulative update from Windows Update
If no patch exists yet
OS downgrades are not safe. Apply the vendor mitigation from the advisory and restrict exposure.

Public exploits and detection

Public code exists for this CVE. Treat unpatched systems as at risk, and only run PoCs in a lab.

Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2018-13989?

grundig smart inter\@ctive firmware: mitigate or apply the listed mitigation. Exact commands for each OS are on this page.

Is CVE-2018-13989 being exploited?

CVE-2018-13989 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2018-13989 affect?

CVE-2018-13989 affects grundig smart inter\@ctive firmware. Severity is high (CVSS 8.8). Grundig Smart Inter@ctive TV 3.0 devices allow CSRF attacks via a POST request to TCP port 8085 containing a predictable ID value, as demonstrated by a /sendrcpackage?keyid=-2544&keysymbol=-4081 request to shut off the device.

How urgent is CVE-2018-13989?

Priority 56/100. High severity; Public exploit reference

References

← Back to latest CVEs

Get the weekly exploited-CVE digest by emailThe CVEs being attacked this week and how to fix them. No spam, unsubscribe any time.