CVE-2018-18561 is a high-severity flaw (CVSS 8.0) affecting accu-chek inform ii firmware, cobas h 232 firmware, coaguchek firmware. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

An issue was discovered in Roche Accu-Chek Inform II Base Unit / Base Unit Hub before 03.01.04 and CoaguChek / cobas h232 Handheld Base Unit before 03.01.04. Insecure permissions in a service interface may allow authenticated attackers in the adjacent network to execute arbitrary commands on the operating system.

Why this priority

  • High severity

A fixed release or distro patch exists.

Risk facts

CVSS score8.0 (High)
Attack vectorAdjacent network
Attack complexityLow
Privileges neededLow
User interactionNone
EPSS exploit chance0.7% (top 48%)
CISA exploited listNo
WeaknessCWE-732
Published2018-11-20
Last modified2026-06-17
Publisher (CNA): MITRE · Vendor: roche

Share: LinkedIn · X · Reddit

Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

roche accu-chek inform ii firmware UPGRADE
Affected: < 03.01.04
Fixed in: 03.01.04
Safe to downgrade to: no unaffected older release
Check your OS release
cat /etc/os-release; uname -r
Debian / Ubuntu
sudo apt update && sudo apt full-upgrade
RHEL / Amazon Linux / Fedora
sudo dnf upgrade --refresh
Windows
Install the latest cumulative update from Windows Update
If no patch exists yet
OS downgrades are not safe. Apply the vendor mitigation from the advisory and restrict exposure.
roche cobas h 232 firmware UPGRADE
Affected: < 03.01.04
Fixed in: 03.01.04
Safe to downgrade to: no unaffected older release
Check your OS release
cat /etc/os-release; uname -r
Debian / Ubuntu
sudo apt update && sudo apt full-upgrade
RHEL / Amazon Linux / Fedora
sudo dnf upgrade --refresh
Windows
Install the latest cumulative update from Windows Update
If no patch exists yet
OS downgrades are not safe. Apply the vendor mitigation from the advisory and restrict exposure.
roche coaguchek firmware UPGRADE
Affected: < 03.01.04
Fixed in: 03.01.04
Safe to downgrade to: no unaffected older release
Check your OS release
cat /etc/os-release; uname -r
Debian / Ubuntu
sudo apt update && sudo apt full-upgrade
RHEL / Amazon Linux / Fedora
sudo dnf upgrade --refresh
Windows
Install the latest cumulative update from Windows Update
If no patch exists yet
OS downgrades are not safe. Apply the vendor mitigation from the advisory and restrict exposure.
roche base unit hub firmware UPGRADE
Affected: < 03.01.04
Fixed in: 03.01.04
Safe to downgrade to: no unaffected older release
Check your OS release
cat /etc/os-release; uname -r
Debian / Ubuntu
sudo apt update && sudo apt full-upgrade
RHEL / Amazon Linux / Fedora
sudo dnf upgrade --refresh
Windows
Install the latest cumulative update from Windows Update
If no patch exists yet
OS downgrades are not safe. Apply the vendor mitigation from the advisory and restrict exposure.
Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2018-18561?

accu-chek inform ii firmware: upgrade to 03.01.04; cobas h 232 firmware: upgrade to 03.01.04; coaguchek firmware: upgrade to 03.01.04. Exact commands for each OS are on this page.

Is CVE-2018-18561 being exploited?

CVE-2018-18561 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2018-18561 affect?

CVE-2018-18561 affects accu-chek inform ii firmware, cobas h 232 firmware, coaguchek firmware. Severity is high (CVSS 8.0). An issue was discovered in Roche Accu-Chek Inform II Base Unit / Base Unit Hub before 03.01.04 and CoaguChek / cobas h232 Handheld Base Unit before 03.01.04. Insecure permissions in a service interface may allow authenticated attackers in t

How urgent is CVE-2018-18561?

Priority 41/100. High severity

Related CVEs

References

← Back to latest CVEs

Get the weekly exploited-CVE digest by emailThe CVEs being attacked this week and how to fix them. No spam, unsubscribe any time.