CVE-2018-6011: The time-based one-time-password (TOTP) function in the application logic of the Green Electronics RainMachine
CVE-2018-6011 is a high-severity flaw (CVSS 8.1) affecting mini-8 firmware. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.
The time-based one-time-password (TOTP) function in the application logic of the Green Electronics RainMachine Mini-8 (2nd generation) uses the administrator's password hash to generate a 6-digit temporary passcode that can be used for remote and local access, aka a "Use of Password Hash Instead of Password for Authentication" issue. This is exploitable by an attacker who discovers a hash value in the rainmachine-settings.sqlite file.
Why this priority
- High severity
- Public exploit reference
- Remotely exploitable, no login, no user action
A fixed release or distro patch exists.
Risk facts
| CVSS score | 8.1 (High) |
| Attack vector | Network (remote) |
| Attack complexity | High |
| Privileges needed | None |
| User interaction | None |
| EPSS exploit chance | 1.1% (top 34%) |
| CISA exploited list | No |
| Weakness | CWE-287 |
| Published | 2018-11-01 |
| Last modified | 2026-06-17 |
Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score
Am I affected?
Timeline
- Published CVE record published
- Updated Record last modified
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.
Quick answers
How do I fix CVE-2018-6011?
mini-8 firmware: upgrade to newer than 4.0.975. Exact commands for each OS are on this page.
Is CVE-2018-6011 being exploited?
CVE-2018-6011 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.
What does CVE-2018-6011 affect?
CVE-2018-6011 affects mini-8 firmware. Severity is high (CVSS 8.1). The time-based one-time-password (TOTP) function in the application logic of the Green Electronics RainMachine Mini-8 (2nd generation) uses the administrator's password hash to generate a 6-digit temporary passcode that can be used for remo
How urgent is CVE-2018-6011?
Priority 55/100. High severity; Public exploit reference; Remotely exploitable, no login, no user action
Software pages
Related CVEs
- CVE-2018-6908 CRITICAL 9.8 UPGRADE UPGRADE An authentication bypass vulnerability exists in the Green Electronics RainMachine Mini-8 (2nd Generation) and
- CVE-2018-6012 CRITICAL 9.8 UPGRADE The 'Weather Service' feature of the Green Electronics RainMachine Mini-8 (2nd generation) allows an attacker