Free and open · new CVEs checked every 20 minutesStatusRSSOpen dataContact

CVE-2018-7526: In TotalAlert Web Application in BeaconMedaes Scroll Medical Air Systems prior to v4107600010.23, by accessing

49
This month
HIGH 7.5REMOTEUPGRADE

CVE-2018-7526 is a high-severity flaw (CVSS 7.5) affecting scroll medical air systems firmware. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

In TotalAlert Web Application in BeaconMedaes Scroll Medical Air Systems prior to v4107600010.23, by accessing a specific uniform resource locator (URL) on the webserver, a malicious user may be able to access information in the application without authenticating.

Why this priority

  • High severity
  • Remotely exploitable, no login, no user action

A fixed release or distro patch exists.

Risk facts

CVSS score7.5 (High)
Attack vectorNetwork (remote)
Attack complexityLow
Privileges neededNone
User interactionNone
EPSS exploit chance1.3% (top 30%)
CISA exploited listNo
WeaknessCWE-425
Published2018-05-24
Last modified2026-06-17
Publisher (CNA): ICS-CERT · Vendor: beaconmedaes

Share: LinkedIn · X · Reddit

Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

beaconmedaes scroll medical air systems firmware UPGRADE
Affected: < 4107600010.23
Fixed in: 4107600010.23
Safe to downgrade to: no unaffected older release
Check your OS release
cat /etc/os-release; uname -r
Debian / Ubuntu
sudo apt update && sudo apt full-upgrade
RHEL / Amazon Linux / Fedora
sudo dnf upgrade --refresh
Windows
Install the latest cumulative update from Windows Update
If no patch exists yet
OS downgrades are not safe. Apply the vendor mitigation from the advisory and restrict exposure.
Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2018-7526?

scroll medical air systems firmware: upgrade to 4107600010.23. Exact commands for each OS are on this page.

Is CVE-2018-7526 being exploited?

CVE-2018-7526 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2018-7526 affect?

CVE-2018-7526 affects scroll medical air systems firmware. Severity is high (CVSS 7.5). In TotalAlert Web Application in BeaconMedaes Scroll Medical Air Systems prior to v4107600010.23, by accessing a specific uniform resource locator (URL) on the webserver, a malicious user may be able to access information in the application

How urgent is CVE-2018-7526?

Priority 49/100. High severity; Remotely exploitable, no login, no user action

Related CVEs

References

← Back to latest CVEs

Get the weekly exploited-CVE digest by emailThe CVEs being attacked this week and how to fix them. No spam, unsubscribe any time.