CVE-2018-8880: Lutron Quantum BACnet Integration 2.0 (firmware 3.2.243) doesn't check for correct user authentication before

60
This week
HIGH 7.5REMOTEMITIGATE

CVE-2018-8880 is a high-severity flaw (CVSS 7.5) affecting quantum bacnet integration firmware. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

Lutron Quantum BACnet Integration 2.0 (firmware 3.2.243) doesn't check for correct user authentication before showing the /deviceIP information, which leads to internal network information disclosure.

Why this priority

  • High severity
  • EPSS top 4%: very likely to be exploited
  • Public exploit reference
  • Remotely exploitable, no login, no user action

No fix is published yet: follow the downgrade or mitigation steps.

Risk facts

CVSS score7.5 (High)
Attack vectorNetwork (remote)
Attack complexityLow
Privileges neededNone
User interactionNone
EPSS exploit chance13.3% (top 4%)
CISA exploited listNo
WeaknessCWE-200
Published2018-04-23
Last modified2026-06-17
Publisher (CNA): MITRE · Vendor: lutron

Share: LinkedIn · X · Reddit

Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

lutron quantum bacnet integration firmware MITIGATE
Affected: 3.2.243
Fixed in: no fixed release known
Safe to downgrade to: a release before 3.2.243
Check your OS release
cat /etc/os-release; uname -r
Debian / Ubuntu
sudo apt update && sudo apt full-upgrade
RHEL / Amazon Linux / Fedora
sudo dnf upgrade --refresh
Windows
Install the latest cumulative update from Windows Update
If no patch exists yet
OS downgrades are not safe. Apply the vendor mitigation from the advisory and restrict exposure.

Public exploits and detection

Public code exists for this CVE. Treat unpatched systems as at risk, and only run PoCs in a lab.

Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2018-8880?

quantum bacnet integration firmware: mitigate or apply the listed mitigation. Exact commands for each OS are on this page.

Is CVE-2018-8880 being exploited?

CVE-2018-8880 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2018-8880 affect?

CVE-2018-8880 affects quantum bacnet integration firmware. Severity is high (CVSS 7.5). Lutron Quantum BACnet Integration 2.0 (firmware 3.2.243) doesn't check for correct user authentication before showing the /deviceIP information, which leads to internal network information disclosure.

How urgent is CVE-2018-8880?

Priority 60/100. High severity; EPSS top 4%: very likely to be exploited; Public exploit reference; Remotely exploitable, no login, no user action

Related CVEs

References

← Back to latest CVEs

Get the weekly exploited-CVE digest by emailThe CVEs being attacked this week and how to fix them. No spam, unsubscribe any time.