Free and open · new CVEs checked every 20 minutesStatusRSSOpen dataContact

CVE-2019-10119: eQ-3 HomeMatic CCU2 devices before 2.41.8 and CCU3 devices before 3.43.16 use session IDs for authentication b

59
This month
CRITICAL 9.8REMOTEUPGRADEUPGRADE

CVE-2019-10119 is a critical-severity flaw (CVSS 9.8) affecting ccu3 firmware, ccu2 firmware. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

eQ-3 HomeMatic CCU2 devices before 2.41.8 and CCU3 devices before 3.43.16 use session IDs for authentication but lack authorization checks. An attacker can obtain a session ID via an invalid login attempt to the RemoteApi account, aka HMCCU-154. This leads to automatic login as admin.

Why this priority

  • Critical severity
  • Remotely exploitable, no login, no user action

A fixed release or distro patch exists.

Risk facts

CVSS score9.8 (Critical)
Attack vectorNetwork (remote)
Attack complexityLow
Privileges neededNone
User interactionNone
EPSS exploit chance2.0% (top 20%)
CISA exploited listNo
WeaknessCWE-306
Published2019-07-10
Last modified2026-06-17
Publisher (CNA): MITRE · Vendor: eq-3

Share: LinkedIn · X · Reddit

Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

eq-3 ccu3 firmware UPGRADE
Affected: < 3.43.16
Fixed in: 3.43.16
Safe to downgrade to: no unaffected older release
Check your OS release
cat /etc/os-release; uname -r
Debian / Ubuntu
sudo apt update && sudo apt full-upgrade
RHEL / Amazon Linux / Fedora
sudo dnf upgrade --refresh
Windows
Install the latest cumulative update from Windows Update
If no patch exists yet
OS downgrades are not safe. Apply the vendor mitigation from the advisory and restrict exposure.
eq-3 ccu2 firmware UPGRADE
Affected: < 2.41.8
Fixed in: 2.41.8
Safe to downgrade to: no unaffected older release
Check your OS release
cat /etc/os-release; uname -r
Debian / Ubuntu
sudo apt update && sudo apt full-upgrade
RHEL / Amazon Linux / Fedora
sudo dnf upgrade --refresh
Windows
Install the latest cumulative update from Windows Update
If no patch exists yet
OS downgrades are not safe. Apply the vendor mitigation from the advisory and restrict exposure.
Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2019-10119?

ccu3 firmware: upgrade to 3.43.16; ccu2 firmware: upgrade to 2.41.8. Exact commands for each OS are on this page.

Is CVE-2019-10119 being exploited?

CVE-2019-10119 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2019-10119 affect?

CVE-2019-10119 affects ccu3 firmware, ccu2 firmware. Severity is critical (CVSS 9.8). eQ-3 HomeMatic CCU2 devices before 2.41.8 and CCU3 devices before 3.43.16 use session IDs for authentication but lack authorization checks. An attacker can obtain a session ID via an invalid login attempt to the RemoteApi account, aka HMCCU

How urgent is CVE-2019-10119?

Priority 59/100. Critical severity; Remotely exploitable, no login, no user action

Related CVEs

References

← Back to latest CVEs

Get the weekly exploited-CVE digest by emailThe CVEs being attacked this week and how to fix them. No spam, unsubscribe any time.