Free and open · new CVEs checked every 20 minutesStatusRSSOpen dataContact

CVE-2019-14359: On BC Vault devices, a side channel for the row-based SSD1309 OLED display was found

23
Routine
LOW 2.4MITIGATE

CVE-2019-14359 is a low-severity flaw (CVSS 2.4) affecting bc vault firmware. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

On BC Vault devices, a side channel for the row-based SSD1309 OLED display was found. The power consumption of each row-based display cycle depends on the number of illuminated pixels, allowing a partial recovery of display contents. For example, a hardware implant in the USB cable might be able to leverage this behavior to recover a data value. In other words, the side channel is relevant only if the attacker has enough control over the device's

Why this priority

  • Public exploit reference

No fix is published yet: follow the downgrade or mitigation steps.

Risk facts

CVSS score2.4 (Low)
Attack vectorPhysical
Attack complexityLow
Privileges neededNone
User interactionNone
EPSS exploit chance0.4% (top 63%)
CISA exploited listNo
WeaknessCWE-203
Published2019-08-12
Last modified2026-06-17
Publisher (CNA): MITRE · Vendor: real-sec

Share: LinkedIn · X · Reddit

Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

real-sec bc vault firmware MITIGATE
Affected: all versions
Fixed in: no fixed release known
Safe to downgrade to: no unaffected older release
Check your OS release
cat /etc/os-release; uname -r
Debian / Ubuntu
sudo apt update && sudo apt full-upgrade
RHEL / Amazon Linux / Fedora
sudo dnf upgrade --refresh
Windows
Install the latest cumulative update from Windows Update
If no patch exists yet
OS downgrades are not safe. Apply the vendor mitigation from the advisory and restrict exposure.
Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2019-14359?

bc vault firmware: mitigate or apply the listed mitigation. Exact commands for each OS are on this page.

Is CVE-2019-14359 being exploited?

CVE-2019-14359 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2019-14359 affect?

CVE-2019-14359 affects bc vault firmware. Severity is low (CVSS 2.4). On BC Vault devices, a side channel for the row-based SSD1309 OLED display was found. The power consumption of each row-based display cycle depends on the number of illuminated pixels, allowing a partial recovery of display contents. For ex

How urgent is CVE-2019-14359?

Priority 23/100. Public exploit reference

Software pages

HashiCorp Vault vulnerabilities

References

← Back to latest CVEs

Get the weekly exploited-CVE digest by emailThe CVEs being attacked this week and how to fix them. No spam, unsubscribe any time.