CVE-2019-15662: An issue was discovered in Rivet Killer Control Center before 2.1.1352
CVE-2019-15662 is a low-severity flaw (CVSS 2.7) affecting killer control center. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.
An issue was discovered in Rivet Killer Control Center before 2.1.1352. IOCTL 0x120444 in KfeCo10X64.sys fails to validate an offset passed as a parameter during a memory operation, leading to an arbitrary read primitive that can be used as part of a chain to escalate privileges.
Why this priority
- No elevated risk signals yet
A fixed release or distro patch exists.
Risk facts
| CVSS score | 2.7 (Low) |
| Attack vector | Network (remote) |
| Attack complexity | Low |
| Privileges needed | High |
| User interaction | None |
| EPSS exploit chance | 0.9% (top 39%) |
| CISA exploited list | No |
| Weakness | CWE-125 |
| Published | 2020-03-20 |
| Last modified | 2026-06-17 |
Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score
Am I affected?
Timeline
- Published CVE record published
- Updated Record last modified
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.
Quick answers
How do I fix CVE-2019-15662?
killer control center: upgrade to 2.1.1352. Exact commands for each OS are on this page.
Is CVE-2019-15662 being exploited?
CVE-2019-15662 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.
What does CVE-2019-15662 affect?
CVE-2019-15662 affects killer control center. Severity is low (CVSS 2.7). An issue was discovered in Rivet Killer Control Center before 2.1.1352. IOCTL 0x120444 in KfeCo10X64.sys fails to validate an offset passed as a parameter during a memory operation, leading to an arbitrary read primitive that can be used as
How urgent is CVE-2019-15662?
Priority 25/100. No elevated risk signals yet.
Related CVEs
- CVE-2021-26258 HIGH 7.8 UPGRADE Improper access control for the Intel(R) Killer(TM) Control Center software before version 2.4.3337.0 may allo
- CVE-2019-15665 HIGH 7.2 UPGRADE An issue was discovered in Rivet Killer Control Center before 2.1.1352
- CVE-2019-15664 LOW 2.7 UPGRADE An issue was discovered in Rivet Killer Control Center before 2.1.1352
- CVE-2019-15663 LOW 2.7 UPGRADE An issue was discovered in Rivet Killer Control Center before 2.1.1352
- CVE-2019-15661 HIGH 7.2 UPGRADE An issue was discovered in Rivet Killer Control Center before 2.1.1352