CVE-2019-16879: The Synergy Systems & Solutions (SSS) HUSKY RTU 6049-E70, with firmware Versions 5.0 and prior, has a Missing
CVE-2019-16879 is a critical-severity flaw (CVSS 9.8) affecting husky rtu 6049-e70 firmware. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.
The Synergy Systems & Solutions (SSS) HUSKY RTU 6049-E70, with firmware Versions 5.0 and prior, has a Missing Authentication for Critical Function (CWE-306) vulnerability. The affected product does not require authentication for TELNET access, which may allow an attacker to change configuration or perform other malicious activities.
Why this priority
- Critical severity
- Remotely exploitable, no login, no user action
A fixed release or distro patch exists.
Risk facts
| CVSS score | 9.8 (Critical) |
| Attack vector | Network (remote) |
| Attack complexity | Low |
| Privileges needed | None |
| User interaction | None |
| EPSS exploit chance | 1.4% (top 28%) |
| CISA exploited list | No |
| Weakness | CWE-306 |
| Published | 2020-04-14 |
| Last modified | 2026-06-17 |
Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score
Am I affected?
Timeline
- Published CVE record published
- Updated Record last modified
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.
Quick answers
How do I fix CVE-2019-16879?
husky rtu 6049-e70 firmware: upgrade to newer than 5.0. Exact commands for each OS are on this page.
Is CVE-2019-16879 being exploited?
CVE-2019-16879 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.
What does CVE-2019-16879 affect?
CVE-2019-16879 affects husky rtu 6049-e70 firmware. Severity is critical (CVSS 9.8). The Synergy Systems & Solutions (SSS) HUSKY RTU 6049-E70, with firmware Versions 5.0 and prior, has a Missing Authentication for Critical Function (CWE-306) vulnerability. The affected product does not require authentication for TELNET acce
How urgent is CVE-2019-16879?
Priority 57/100. Critical severity; Remotely exploitable, no login, no user action
Related CVEs
- CVE-2020-7802 MEDIUM 5.3 UPGRADE The Synergy Systems & Solutions (SSS) HUSKY RTU 6049-E70, with firmware Versions 5.0 and prior, has an Incorre
- CVE-2020-7801 MEDIUM 5.3 UPGRADE The Synergy Systems & Solutions (SSS) HUSKY RTU 6049-E70, with firmware Versions 5.0 and prior, has an Exposur
- CVE-2020-7800 HIGH 8.2 UPGRADE The Synergy Systems & Solutions (SSS) HUSKY RTU 6049-E70, with firmware Versions 5.0 and prior, has an Imprope
- CVE-2019-20046 CRITICAL 9.8 UPGRADE The Synergy Systems & Solutions PLC & RTU system has a vulnerability in HUSKY RTU 6049-E70 firmware versions 5
- CVE-2019-20045 HIGH 7.5 UPGRADE The Synergy Systems & Solutions PLC & RTU system has a vulnerability in HUSKY RTU 6049-E70 firmware versions 5