Free and open · new CVEs checked every 20 minutesStatusRSSOpen dataContact

CVE-2019-9579: An issue was discovered in Illumos in Nexenta NexentaStor 4.0.5 and 5.1.2, and other products

40
This month
HIGH 8.1MITIGATEMITIGATE

CVE-2019-9579 is a high-severity flaw (CVSS 8.1) affecting illumos, solaris. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

An issue was discovered in Illumos in Nexenta NexentaStor 4.0.5 and 5.1.2, and other products. The SMB server allows an attacker to have unintended access, e.g., an attacker with WRITE_XATTR can change permissions. This occurs because of a combination of three factors: ZFS extended attributes are used to implement NT named streams, the SMB protocol requires implementations to have open handle semantics similar to those of NTFS, and the SMB server

Why this priority

  • High severity

No fix is published yet: follow the downgrade or mitigation steps.

Risk facts

CVSS score8.1 (High)
Attack vectorNetwork (remote)
Attack complexityLow
Privileges neededLow
User interactionNone
EPSS exploit chance0.5% (top 55%)
CISA exploited listNo
WeaknessCWE-276
Published2022-12-26
Last modified2026-06-17
Publisher (CNA): MITRE · Vendor: illumos · oracle

Share: LinkedIn · X · Reddit

Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

illumos illumos MITIGATE
Affected: all versions
Fixed in: no fixed release known
Safe to downgrade to: no unaffected older release
1. Check installed version
apt-cache policy illumos || rpm -q illumos || illumos --version
No fixed or unaffected release known
Apply the vendor mitigation from the advisory, disable the affected feature, or restrict network access.
oracle solaris MITIGATE
Affected: 11
Fixed in: no fixed release known
Safe to downgrade to: a release before 11
Check your OS release
cat /etc/os-release; uname -r
Debian / Ubuntu
sudo apt update && sudo apt full-upgrade
RHEL / Amazon Linux / Fedora
sudo dnf upgrade --refresh
Windows
Install the latest cumulative update from Windows Update
If no patch exists yet
OS downgrades are not safe. Apply the vendor mitigation from the advisory and restrict exposure.
Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2019-9579?

illumos: mitigate or apply the listed mitigation; solaris: mitigate or apply the listed mitigation. Exact commands for each OS are on this page.

Is CVE-2019-9579 being exploited?

CVE-2019-9579 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2019-9579 affect?

CVE-2019-9579 affects illumos, solaris. Severity is high (CVSS 8.1). An issue was discovered in Illumos in Nexenta NexentaStor 4.0.5 and 5.1.2, and other products. The SMB server allows an attacker to have unintended access, e.g., an attacker with WRITE_XATTR can change permissions. This occurs because of a

How urgent is CVE-2019-9579?

Priority 40/100. High severity

Related CVEs

References

← Back to latest CVEs

Get the weekly exploited-CVE digest by emailThe CVEs being attacked this week and how to fix them. No spam, unsubscribe any time.