Free and open · new CVEs checked every 20 minutesStatusRSSOpen dataContact

CVE-2020-17437: An issue was discovered in uIP 1.0, as used in Contiki 3.0 and other products

55
This month
HIGH 8.2REMOTEUPGRADEUPGRADEUPGRADE

CVE-2020-17437 is a high-severity flaw (CVSS 8.2) affecting uip, open-iscsi, sentron 3va com100 firmware. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

An issue was discovered in uIP 1.0, as used in Contiki 3.0 and other products. When the Urgent flag is set in a TCP packet, and the stack is configured to ignore the urgent data, the stack attempts to use the value of the Urgent pointer bytes to separate the Urgent data from the normal data, by calculating the offset at which the normal data should be present in the global buffer. However, the length of this offset is not checked; therefore, for

Why this priority

  • High severity
  • Remotely exploitable, no login, no user action

A fixed release or distro patch exists.

Risk facts

CVSS score8.2 (High)
Attack vectorNetwork (remote)
Attack complexityLow
Privileges neededNone
User interactionNone
EPSS exploit chance2.8% (top 14%)
CISA exploited listNo
WeaknessCWE-787
Published2020-12-11
Last modified2026-06-17
Publisher (CNA): MITRE · Vendor: open-iscsi project · siemens · uip project

Share: LinkedIn · X · Reddit

Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

uip project uip UPGRADE
Affected: <= 1.0
Fixed in: newer than 1.0
Safe to downgrade to: no unaffected older release
1. Check installed version
apt-cache policy uip || rpm -q uip || uip --version
2. UPGRADE to newer than 1.0 (Debian / Ubuntu)
sudo apt update && sudo apt install --only-upgrade uip
2. UPGRADE (RHEL / Amazon Linux / Fedora)
sudo dnf upgrade uip
Note
Distros often backport fixes without changing the version number. Confirm with the distro advisory or changelog.
open-iscsi project open-iscsi UPGRADE
Affected: <= 2.1.7
Fixed in: newer than 2.1.7
Safe to downgrade to: no unaffected older release
1. Check installed version
apt-cache policy open-iscsi || rpm -q open-iscsi || open-iscsi --version
2. UPGRADE to newer than 2.1.7 (Debian / Ubuntu)
sudo apt update && sudo apt install --only-upgrade open-iscsi
2. UPGRADE (RHEL / Amazon Linux / Fedora)
sudo dnf upgrade open-iscsi
Note
Distros often backport fixes without changing the version number. Confirm with the distro advisory or changelog.
siemens sentron 3va com100 firmware UPGRADE
Affected: < 4.4.1
Fixed in: 4.4.1
Safe to downgrade to: no unaffected older release
Check your OS release
cat /etc/os-release; uname -r
Debian / Ubuntu
sudo apt update && sudo apt full-upgrade
RHEL / Amazon Linux / Fedora
sudo dnf upgrade --refresh
Windows
Install the latest cumulative update from Windows Update
If no patch exists yet
OS downgrades are not safe. Apply the vendor mitigation from the advisory and restrict exposure.
siemens sentron 3va com800 firmware UPGRADE
Affected: < 4.4.1
Fixed in: 4.4.1
Safe to downgrade to: no unaffected older release
Check your OS release
cat /etc/os-release; uname -r
Debian / Ubuntu
sudo apt update && sudo apt full-upgrade
RHEL / Amazon Linux / Fedora
sudo dnf upgrade --refresh
Windows
Install the latest cumulative update from Windows Update
If no patch exists yet
OS downgrades are not safe. Apply the vendor mitigation from the advisory and restrict exposure.
siemens sentron 3va dsp800 firmware UPGRADE
Affected: < 4.0
Fixed in: 4.0
Safe to downgrade to: no unaffected older release
Check your OS release
cat /etc/os-release; uname -r
Debian / Ubuntu
sudo apt update && sudo apt full-upgrade
RHEL / Amazon Linux / Fedora
sudo dnf upgrade --refresh
Windows
Install the latest cumulative update from Windows Update
If no patch exists yet
OS downgrades are not safe. Apply the vendor mitigation from the advisory and restrict exposure.
siemens sentron pac2200 clp firmware MITIGATE
Affected: all versions
Fixed in: no fixed release known
Safe to downgrade to: no unaffected older release
Check your OS release
cat /etc/os-release; uname -r
Debian / Ubuntu
sudo apt update && sudo apt full-upgrade
RHEL / Amazon Linux / Fedora
sudo dnf upgrade --refresh
Windows
Install the latest cumulative update from Windows Update
If no patch exists yet
OS downgrades are not safe. Apply the vendor mitigation from the advisory and restrict exposure.
Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2020-17437?

uip: upgrade to newer than 1.0; open-iscsi: upgrade to newer than 2.1.7; sentron 3va com100 firmware: upgrade to 4.4.1. Exact commands for each OS are on this page.

Is CVE-2020-17437 being exploited?

CVE-2020-17437 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2020-17437 affect?

CVE-2020-17437 affects uip, open-iscsi, sentron 3va com100 firmware. Severity is high (CVSS 8.2). An issue was discovered in uIP 1.0, as used in Contiki 3.0 and other products. When the Urgent flag is set in a TCP packet, and the stack is configured to ignore the urgent data, the stack attempts to use the value of the Urgent pointer byt

How urgent is CVE-2020-17437?

Priority 55/100. High severity; Remotely exploitable, no login, no user action

Software pages

Siemens vulnerabilities

Related CVEs

References

← Back to latest CVEs

Get the weekly exploited-CVE digest by emailThe CVEs being attacked this week and how to fix them. No spam, unsubscribe any time.