Free and open · new CVEs checked every 20 minutesStatusRSSOpen dataContact

CVE-2020-20486: IEC104 v1.0 contains a stack-buffer overflow in the parameter Iec10x_Sta_Addr.

53
This week
HIGH 7.5REMOTEDOWNGRADE

CVE-2020-20486 is a high-severity flaw (CVSS 7.5) affecting iec104. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

IEC104 v1.0 contains a stack-buffer overflow in the parameter Iec10x_Sta_Addr.

Why this priority

  • High severity
  • Public exploit reference
  • Remotely exploitable, no login, no user action

No fix is published yet: follow the downgrade or mitigation steps.

Risk facts

CVSS score7.5 (High)
Attack vectorNetwork (remote)
Attack complexityLow
Privileges neededNone
User interactionNone
EPSS exploit chance1.1% (top 35%)
CISA exploited listNo
WeaknessCWE-787
Published2021-08-31
Last modified2026-06-17
Publisher (CNA): MITRE · Vendor: iec104 project

Share: LinkedIn · X · Reddit

Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

iec104 project iec104 DOWNGRADE
Affected: 1.0
Fixed in: no fixed release known
Safe to downgrade to: a release before 1.0
1. Check installed version
apt-cache policy iec104 || rpm -q iec104 || iec104 --version
2. No fixed release: DOWNGRADE to a release before 1.0 (Debian / Ubuntu)
apt-cache madison iec104 sudo apt install iec104=<VERSION_BEFORE_1.0> sudo apt-mark hold iec104
2. No fixed release: DOWNGRADE (RHEL / Amazon Linux / Fedora)
dnf --showduplicates list iec104 sudo dnf downgrade iec104-<VERSION_BEFORE_1.0> sudo dnf versionlock add iec104
Downgrade risk
Downgrading can break dependent software and may reopen older bugs. Read the distro advisory first and test on a non-production host.
After downgrade
Restart the service, and keep the package held until a fixed release ships.
Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2020-20486?

iec104: downgrade or apply the listed mitigation. Exact commands for each OS are on this page.

Is CVE-2020-20486 being exploited?

CVE-2020-20486 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2020-20486 affect?

CVE-2020-20486 affects iec104. Severity is high (CVSS 7.5). IEC104 v1.0 contains a stack-buffer overflow in the parameter Iec10x_Sta_Addr.

How urgent is CVE-2020-20486?

Priority 53/100. High severity; Public exploit reference; Remotely exploitable, no login, no user action

Related CVEs

References

← Back to latest CVEs

Get the weekly exploited-CVE digest by emailThe CVEs being attacked this week and how to fix them. No spam, unsubscribe any time.