CVE-2020-3924: DVR firmware in TAT-76 and TAT-77 series of products, provided by TONNET do not properly verify patch files
40
This month
MEDIUM 6.4UPGRADEUPGRADEUPGRADE
CVE-2020-3924 is a medium-severity flaw (CVSS 6.4) affecting tat-77104g1 firmware, tat-70432n firmware, tat-71416g1 firmware. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.
DVR firmware in TAT-76 and TAT-77 series of products, provided by TONNET do not properly verify patch files. Attackers can inject a specific command into a patch file and gain access to the system.
Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score
Am I affected?
Timeline
Published CVE record published
Updated Record last modified
tonnet tat-77104g1 firmware UPGRADE
Affected: <= tat-77104g1_20190107
Fixed in: newer than tat-77104g1_20190107
Safe to downgrade to: no unaffected older release
Check your OS release
cat /etc/os-release; uname -r
Debian / Ubuntu
sudo apt update && sudo apt full-upgrade
RHEL / Amazon Linux / Fedora
sudo dnf upgrade --refresh
Windows
Install the latest cumulative update from Windows Update
If no patch exists yet
OS downgrades are not safe. Apply the vendor mitigation from the advisory and restrict exposure.
tonnet tat-70432n firmware UPGRADE
Affected: <= tat-77208g1_20181225
Fixed in: newer than tat-77208g1_20181225
Safe to downgrade to: no unaffected older release
Check your OS release
cat /etc/os-release; uname -r
Debian / Ubuntu
sudo apt update && sudo apt full-upgrade
RHEL / Amazon Linux / Fedora
sudo dnf upgrade --refresh
Windows
Install the latest cumulative update from Windows Update
If no patch exists yet
OS downgrades are not safe. Apply the vendor mitigation from the advisory and restrict exposure.
tonnet tat-71416g1 firmware UPGRADE
Affected: <= tat-71416g1_20181225
Fixed in: newer than tat-71416g1_20181225
Safe to downgrade to: no unaffected older release
Check your OS release
cat /etc/os-release; uname -r
Debian / Ubuntu
sudo apt update && sudo apt full-upgrade
RHEL / Amazon Linux / Fedora
sudo dnf upgrade --refresh
Windows
Install the latest cumulative update from Windows Update
If no patch exists yet
OS downgrades are not safe. Apply the vendor mitigation from the advisory and restrict exposure.
tonnet tat-71832g1 firmware UPGRADE
Affected: <= tat-71832g1_20190510
Fixed in: newer than tat-71832g1_20190510
Safe to downgrade to: no unaffected older release
Check your OS release
cat /etc/os-release; uname -r
Debian / Ubuntu
sudo apt update && sudo apt full-upgrade
RHEL / Amazon Linux / Fedora
sudo dnf upgrade --refresh
Windows
Install the latest cumulative update from Windows Update
If no patch exists yet
OS downgrades are not safe. Apply the vendor mitigation from the advisory and restrict exposure.
tonnet tat-76104g3 firmware UPGRADE
Affected: <= 20181220_76104g3
Fixed in: newer than 20181220_76104g3
Safe to downgrade to: no unaffected older release
Check your OS release
cat /etc/os-release; uname -r
Debian / Ubuntu
sudo apt update && sudo apt full-upgrade
RHEL / Amazon Linux / Fedora
sudo dnf upgrade --refresh
Windows
Install the latest cumulative update from Windows Update
If no patch exists yet
OS downgrades are not safe. Apply the vendor mitigation from the advisory and restrict exposure.
tonnet tat-76108g3 firmware UPGRADE
Affected: <= 20181221_76208g3
Fixed in: newer than 20181221_76208g3
Safe to downgrade to: no unaffected older release
Check your OS release
cat /etc/os-release; uname -r
Debian / Ubuntu
sudo apt update && sudo apt full-upgrade
RHEL / Amazon Linux / Fedora
sudo dnf upgrade --refresh
Windows
Install the latest cumulative update from Windows Update
If no patch exists yet
OS downgrades are not safe. Apply the vendor mitigation from the advisory and restrict exposure.
Verify at the official sourceNVD · CVE Program · Report a problem with this page Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.
Quick answers
How do I fix CVE-2020-3924?
tat-77104g1 firmware: upgrade to newer than tat-77104g1_20190107; tat-70432n firmware: upgrade to newer than tat-77208g1_20181225; tat-71416g1 firmware: upgrade to newer than tat-71416g1_20181225. Exact commands for each OS are on this page.
Is CVE-2020-3924 being exploited?
CVE-2020-3924 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.
What does CVE-2020-3924 affect?
CVE-2020-3924 affects tat-77104g1 firmware, tat-70432n firmware, tat-71416g1 firmware. Severity is medium (CVSS 6.4). DVR firmware in TAT-76 and TAT-77 series of products, provided by TONNET do not properly verify patch files. Attackers can inject a specific command into a patch file and gain access to the system.
How urgent is CVE-2020-3924?
Priority 40/100. No elevated risk signals yet.
Related CVEs
CVE-2020-3923HIGH 8.1UPGRADEUPGRADE DVR firmware in TAT-76 and TAT-77 series of products, provided by TONNET, contain misconfigured authentication