CVE-2021-36707: In ProLink PRC2402M V1.0.18 and older, the set_ledonoff function in the adm.cgi binary, accessible with a page
CVE-2021-36707 is a critical-severity flaw (CVSS 9.8) affecting prc2402m firmware. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.
In ProLink PRC2402M V1.0.18 and older, the set_ledonoff function in the adm.cgi binary, accessible with a page parameter value of ledonoff contains a trivial command injection where the value of the led_cmd parameter is passed directly to do_system.
Why this priority
- Critical severity
- Public exploit reference
- Remotely exploitable, no login, no user action
A fixed release or distro patch exists.
Risk facts
| CVSS score | 9.8 (Critical) |
| Attack vector | Network (remote) |
| Attack complexity | Low |
| Privileges needed | None |
| User interaction | None |
| EPSS exploit chance | 2.6% (top 15%) |
| CISA exploited list | No |
| Weakness | CWE-77 |
| Published | 2021-08-06 |
| Last modified | 2026-06-17 |
Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score
Am I affected?
Timeline
- Published CVE record published
- Updated Record last modified
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.
Quick answers
How do I fix CVE-2021-36707?
prc2402m firmware: upgrade to newer than 1.0.18. Exact commands for each OS are on this page.
Is CVE-2021-36707 being exploited?
CVE-2021-36707 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.
What does CVE-2021-36707 affect?
CVE-2021-36707 affects prc2402m firmware. Severity is critical (CVSS 9.8). In ProLink PRC2402M V1.0.18 and older, the set_ledonoff function in the adm.cgi binary, accessible with a page parameter value of ledonoff contains a trivial command injection where the value of the led_cmd parameter is passed directly to d
How urgent is CVE-2021-36707?
Priority 66/100. Critical severity; Public exploit reference; Remotely exploitable, no login, no user action
Related CVEs
- CVE-2021-36708 HIGH 7.5 UPGRADE In ProLink PRC2402M V1.0.18 and older, the set_sys_init function in the login.cgi binary allows an attacker to
- CVE-2021-36706 CRITICAL 9.8 UPGRADE In ProLink PRC2402M V1.0.18 and older, the set_sys_cmd function in the adm.cgi binary, accessible with a page
- CVE-2021-36705 CRITICAL 9.8 UPGRADE In ProLink PRC2402M V1.0.18 and older, the set_TR069 function in the adm.cgi binary, accessible with a page pa