Free and open · new CVEs checked every 20 minutesStatusRSSOpen dataContact

CVE-2021-37162: A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by re

61
This week
CRITICAL 9.8REMOTEUPGRADE

CVE-2021-37162 is a critical-severity flaw (CVSS 9.8) affecting hmi-3 control panel firmware. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. If an attacker sends a malformed UDP message, a buffer underflow occurs, leading to an out-of-bounds copy and possible remote code execution.

Why this priority

  • Critical severity
  • Remotely exploitable, no login, no user action

A fixed release or distro patch exists.

Risk facts

CVSS score9.8 (Critical)
Attack vectorNetwork (remote)
Attack complexityLow
Privileges neededNone
User interactionNone
EPSS exploit chance3.3% (top 12%)
CISA exploited listNo
WeaknessCWE-120
Published2021-08-02
Last modified2026-06-17
Publisher (CNA): MITRE · Vendor: swisslog-healthcare

Share: LinkedIn · X · Reddit

Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

swisslog-healthcare hmi-3 control panel firmware UPGRADE
Affected: < 7.2.5.7
Fixed in: 7.2.5.7
Safe to downgrade to: no unaffected older release
Check your OS release
cat /etc/os-release; uname -r
Debian / Ubuntu
sudo apt update && sudo apt full-upgrade
RHEL / Amazon Linux / Fedora
sudo dnf upgrade --refresh
Windows
Install the latest cumulative update from Windows Update
If no patch exists yet
OS downgrades are not safe. Apply the vendor mitigation from the advisory and restrict exposure.
Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2021-37162?

hmi-3 control panel firmware: upgrade to 7.2.5.7. Exact commands for each OS are on this page.

Is CVE-2021-37162 being exploited?

CVE-2021-37162 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2021-37162 affect?

CVE-2021-37162 affects hmi-3 control panel firmware. Severity is critical (CVSS 9.8). A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. If an attacker sends a malformed UDP message, a buffer underflow occurs

How urgent is CVE-2021-37162?

Priority 61/100. Critical severity; Remotely exploitable, no login, no user action

Related CVEs

References

← Back to latest CVEs

Get the weekly exploited-CVE digest by emailThe CVEs being attacked this week and how to fix them. No spam, unsubscribe any time.