Free and open · new CVEs checked every 20 minutesStatusRSSOpen dataContact

CVE-2022-23129: Plaintext Storage of a Password vulnerability in Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01)

21
Routine
MEDIUM 5.5UPGRADEUPGRADE

CVE-2022-23129 is a medium-severity flaw (CVSS 5.5) affecting genesis64, mc works64. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

Plaintext Storage of a Password vulnerability in Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior and ICONICS GENESIS64 versions 10.90 to 10.97 allows a local authenticated attacker to gain authentication information and to access the database illegally. This is because when configuration information of GridWorX, a database linkage function of GENESIS64 and MC Works64, is exported to a CSV file, the authentication informatio

Why this priority

  • No elevated risk signals yet

A fixed release or distro patch exists.

Risk facts

CVSS score5.5 (Medium)
Attack vectorLocal
Attack complexityLow
Privileges neededLow
User interactionNone
EPSS exploit chance0.2% (top 92%)
CISA exploited listNo
WeaknessCWE-312
Published2022-01-21
Last modified2026-06-17
Publisher (CNA): Mitsubishi Electric Corporation · Vendor: iconics · mitsubishielectric

Share: LinkedIn · X · Reddit

Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

iconics genesis64 UPGRADE
Affected: >= 10.90 and <= 10.97
Fixed in: newer than 10.97
Safe to downgrade to: a release before 10.90
1. Check installed version
apt-cache policy genesis64 || rpm -q genesis64 || genesis64 --version
2. UPGRADE to newer than 10.97 (Debian / Ubuntu)
sudo apt update && sudo apt install --only-upgrade genesis64
2. UPGRADE (RHEL / Amazon Linux / Fedora)
sudo dnf upgrade genesis64
Note
Distros often backport fixes without changing the version number. Confirm with the distro advisory or changelog.
3. If no update is available yet, DOWNGRADE to a release before 10.90 (Debian / Ubuntu)
apt-cache madison genesis64 sudo apt install genesis64=<VERSION_BEFORE_10.90> sudo apt-mark hold genesis64
3. If no update is available yet, DOWNGRADE (RHEL / Amazon Linux / Fedora)
dnf --showduplicates list genesis64 sudo dnf downgrade genesis64-<VERSION_BEFORE_10.90> sudo dnf versionlock add genesis64
Downgrade risk
Downgrading can break dependent software and may reopen older bugs. Read the distro advisory first and test on a non-production host.
After downgrade
Restart the service, and keep the package held until a fixed release ships.
mitsubishielectric mc works64 UPGRADE
Affected: < 10.95.210.01
Fixed in: 10.95.210.01
Safe to downgrade to: no unaffected older release
1. Check installed version
apt-cache policy mc-works64 || rpm -q mc-works64 || mc-works64 --version
2. UPGRADE to 10.95.210.01 (Debian / Ubuntu)
sudo apt update && sudo apt install --only-upgrade mc-works64
2. UPGRADE (RHEL / Amazon Linux / Fedora)
sudo dnf upgrade mc-works64
Note
Distros often backport fixes without changing the version number. Confirm with the distro advisory or changelog.
Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2022-23129?

genesis64: upgrade to newer than 10.97; mc works64: upgrade to 10.95.210.01. Exact commands for each OS are on this page.

Is CVE-2022-23129 being exploited?

CVE-2022-23129 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2022-23129 affect?

CVE-2022-23129 affects genesis64, mc works64. Severity is medium (CVSS 5.5). Plaintext Storage of a Password vulnerability in Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior and ICONICS GENESIS64 versions 10.90 to 10.97 allows a local authenticated attacker to gain authentication information a

How urgent is CVE-2022-23129?

Priority 21/100. No elevated risk signals yet.

Software pages

Mitsubishi Electric vulnerabilities

Related CVEs

References

← Back to latest CVEs

Get the weekly exploited-CVE digest by emailThe CVEs being attacked this week and how to fix them. No spam, unsubscribe any time.