CVE-2022-25836: Bluetooth® Low Energy Pairing in Bluetooth Core Specification v4.0 through v5.3 may permit an unauthenticated
CVE-2022-25836 is a high-severity flaw (CVSS 7.5) affecting bluetooth core specification. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.
Bluetooth® Low Energy Pairing in Bluetooth Core Specification v4.0 through v5.3 may permit an unauthenticated MITM to acquire credentials with two pairing devices via adjacent access when the MITM negotiates Legacy Passkey Pairing with the pairing Initiator and Secure Connections Passkey Pairing with the pairing Responder and brute forces the Passkey entered by the user into the Initiator. The MITM attacker can use the identified Passkey value to
Why this priority
- High severity
A fixed release or distro patch exists.
Risk facts
| CVSS score | 7.5 (High) |
| Attack vector | Adjacent network |
| Attack complexity | High |
| Privileges needed | None |
| User interaction | Required |
| EPSS exploit chance | 0.4% (top 70%) |
| CISA exploited list | No |
| Weakness | CWE-294 |
| Published | 2022-12-12 |
| Last modified | 2026-06-17 |
Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score
Am I affected?
Timeline
- Published CVE record published
- Updated Record last modified
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.
Quick answers
How do I fix CVE-2022-25836?
bluetooth core specification: upgrade to newer than 5.3. Exact commands for each OS are on this page.
Is CVE-2022-25836 being exploited?
CVE-2022-25836 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.
What does CVE-2022-25836 affect?
CVE-2022-25836 affects bluetooth core specification. Severity is high (CVSS 7.5). Bluetooth® Low Energy Pairing in Bluetooth Core Specification v4.0 through v5.3 may permit an unauthenticated MITM to acquire credentials with two pairing devices via adjacent access when the MITM negotiates Legacy Passkey Pairing with the
How urgent is CVE-2022-25836?
Priority 34/100. High severity
Software pages
Related CVEs
- CVE-2023-24023 MEDIUM 6.8 UPGRADE UPGRADE Bluetooth BR/EDR devices with Secure Simple Pairing and Secure Connections pairing in Bluetooth Core Specifica
- CVE-2022-25837 HIGH 7.5 UPGRADE Bluetooth® Pairing in Bluetooth Core Specification v1.0B through v5.3 may permit an unauthenticated MITM to ac
- CVE-2022-24695 MEDIUM 4.3 UPGRADE Bluetooth Classic in Bluetooth Core Specification through 5.3 does not properly conceal device information for
- CVE-2020-35473 MEDIUM 4.3 UPGRADE An information leakage vulnerability in the Bluetooth Low Energy advertisement scan response in Bluetooth Core