Free and open · new CVEs checked every 20 minutesStatusRSSOpen dataContact

CVE-2022-31808: A vulnerability has been identified in SiPass integrated AC5102 (ACC-G2) (All versions < V2.85.44), SiPass int

31
Routine
HIGH 7.8UPGRADEUPGRADE

CVE-2022-31808 is a high-severity flaw (CVSS 7.8) affecting sipass integrated acc-ap firmware, sipass integrated ac5102 \(acc-g2\) firmware. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

A vulnerability has been identified in SiPass integrated AC5102 (ACC-G2) (All versions < V2.85.44), SiPass integrated ACC-AP (All versions < V2.85.43). Affected devices improperly sanitize user input on the telnet command line interface. This could allow an authenticated user to escalate privileges by injecting arbitrary commands that are executed with root privileges.

Why this priority

  • High severity

A fixed release or distro patch exists.

Risk facts

CVSS score7.8 (High)
Attack vectorLocal
Attack complexityLow
Privileges neededLow
User interactionNone
EPSS exploit chance0.2% (top 87%)
CISA exploited listNo
WeaknessCWE-20
Published2023-02-14
Last modified2026-10-24
Publisher (CNA): Siemens AG · Vendor: siemens

Share: LinkedIn · X · Reddit

Last updated 2026-10-24 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

siemens sipass integrated acc-ap firmware UPGRADE
Affected: < 2.85.43
Fixed in: 2.85.43
Safe to downgrade to: no unaffected older release
Check your OS release
cat /etc/os-release; uname -r
Debian / Ubuntu
sudo apt update && sudo apt full-upgrade
RHEL / Amazon Linux / Fedora
sudo dnf upgrade --refresh
Windows
Install the latest cumulative update from Windows Update
If no patch exists yet
OS downgrades are not safe. Apply the vendor mitigation from the advisory and restrict exposure.
siemens sipass integrated ac5102 \(acc-g2\) firmware UPGRADE
Affected: < 2.85.44
Fixed in: 2.85.44
Safe to downgrade to: no unaffected older release
Check your OS release
cat /etc/os-release; uname -r
Debian / Ubuntu
sudo apt update && sudo apt full-upgrade
RHEL / Amazon Linux / Fedora
sudo dnf upgrade --refresh
Windows
Install the latest cumulative update from Windows Update
If no patch exists yet
OS downgrades are not safe. Apply the vendor mitigation from the advisory and restrict exposure.

Exact fixes by distribution

Fedora 46 · uv · FIXED · 0.13.5-2.fc46 · FEDORA-2026-0a45cde16b · source
sudo dnf upgrade --advisory=FEDORA-2026-0a45cde16b
Fedora ELN · oo7 · FIXED · 0.7.0~beta-3.eln159 · FEDORA-2026-f348262964 · source
sudo dnf upgrade --advisory=FEDORA-2026-f348262964
Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2022-31808?

sipass integrated acc-ap firmware: upgrade to 2.85.43; sipass integrated ac5102 \(acc-g2\) firmware: upgrade to 2.85.44. Exact commands for each OS are on this page.

Is CVE-2022-31808 being exploited?

CVE-2022-31808 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2022-31808 affect?

CVE-2022-31808 affects sipass integrated acc-ap firmware, sipass integrated ac5102 \(acc-g2\) firmware. Severity is high (CVSS 7.8). A vulnerability has been identified in SiPass integrated AC5102 (ACC-G2) (All versions < V2.85.44), SiPass integrated ACC-AP (All versions < V2.85.43). Affected devices improperly sanitize user input on the telnet command line interface.

How urgent is CVE-2022-31808?

Priority 31/100. High severity