Free and open · new CVEs checked every 20 minutesStatusRSSOpen dataContact

CVE-2023-22583: The Danfoss AK-EM100 web forms allow for SQL injection in the login forms.

54
This month
CRITICAL 10.0REMOTEUPGRADE

CVE-2023-22583 is a critical-severity flaw (CVSS 10.0) affecting ak-em100 firmware. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

The Danfoss AK-EM100 web forms allow for SQL injection in the login forms.

Why this priority

  • Critical severity
  • Remotely exploitable, no login, no user action

A fixed release or distro patch exists.

Risk facts

CVSS score10.0 (Critical)
Attack vectorNetwork (remote)
Attack complexityLow
Privileges neededNone
User interactionNone
EPSS exploit chance0.8% (top 45%)
CISA exploited listNo
WeaknessCWE-89
Published2023-06-11
Last modified2026-06-17
Publisher (CNA): Dutch Institute for Vulnerability Disclosure · Vendor: danfoss

Share: LinkedIn · X · Reddit

Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

danfoss ak-em100 firmware UPGRADE
Affected: < 2.2.0.12
Fixed in: 2.2.0.12
Safe to downgrade to: no unaffected older release
Check your OS release
cat /etc/os-release; uname -r
Debian / Ubuntu
sudo apt update && sudo apt full-upgrade
RHEL / Amazon Linux / Fedora
sudo dnf upgrade --refresh
Windows
Install the latest cumulative update from Windows Update
If no patch exists yet
OS downgrades are not safe. Apply the vendor mitigation from the advisory and restrict exposure.
Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2023-22583?

ak-em100 firmware: upgrade to 2.2.0.12. Exact commands for each OS are on this page.

Is CVE-2023-22583 being exploited?

CVE-2023-22583 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2023-22583 affect?

CVE-2023-22583 affects ak-em100 firmware. Severity is critical (CVSS 10.0). The Danfoss AK-EM100 web forms allow for SQL injection in the login forms.

How urgent is CVE-2023-22583?

Priority 54/100. Critical severity; Remotely exploitable, no login, no user action

Related CVEs

References

← Back to latest CVEs

Get the weekly exploited-CVE digest by emailThe CVEs being attacked this week and how to fix them. No spam, unsubscribe any time.