CVE-2023-29106: A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions >= V2.0 < V2.1), SIMATIC Cl
37
Routine
MEDIUM 5.3REMOTEMITIGATEMITIGATE
CVE-2023-29106 is a medium-severity flaw (CVSS 5.3) affecting 6gk1411-1ac00 firmware, 6gk1411-5ac00 firmware. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions >= V2.0 < V2.1). The export endpoint is accessible via REST API without authentication. This could allow an unauthenticated remote attacker to download the files available via the endpoint.
Why this priority
- Remotely exploitable, no login, no user action
No fix is published yet: follow the downgrade or mitigation steps.
Risk facts
| CVSS score | 5.3 (Medium) |
| Attack vector | Network (remote) |
| Attack complexity | Low |
| Privileges needed | None |
| User interaction | None |
| EPSS exploit chance | 0.7% (top 47%) |
| CISA exploited list | No |
| Weakness | CWE-200 |
| Published | 2023-05-09 |
| Last modified | 2026-10-23 |
Publisher (CNA): Siemens AG · Vendor: siemens
Am I affected?
Timeline
- Published CVE record published
- Updated Record last modified
siemens 6gk1411-1ac00 firmware MITIGATE
Affected: 2.0
Fixed in: no fixed release known
Safe to downgrade to: a release before 2.0
Check your OS release
cat /etc/os-release; uname -r
Debian / Ubuntu
sudo apt update && sudo apt full-upgrade
RHEL / Amazon Linux / Fedora
sudo dnf upgrade --refresh
Windows
Install the latest cumulative update from Windows Update
If no patch exists yet
OS downgrades are not safe. Apply the vendor mitigation from the advisory and restrict exposure.
siemens 6gk1411-5ac00 firmware MITIGATE
Affected: 2.0
Fixed in: no fixed release known
Safe to downgrade to: a release before 2.0
Check your OS release
cat /etc/os-release; uname -r
Debian / Ubuntu
sudo apt update && sudo apt full-upgrade
RHEL / Amazon Linux / Fedora
sudo dnf upgrade --refresh
Windows
Install the latest cumulative update from Windows Update
If no patch exists yet
OS downgrades are not safe. Apply the vendor mitigation from the advisory and restrict exposure.
Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.
Related CVEs
- CVE-2023-29105 MEDIUM 5.9 UPGRADE UPGRADE A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions >= V2.0 < V2.1), SIMATIC Cl