Free and open · new CVEs checked every 20 minutesStatusRSSOpen dataContact

CVE-2023-31172: An Incomplete Filtering of Special Elements vulnerability in the Schweitzer Engineering Laboratories SEL-5030

28
Routine
MEDIUM 5.9UPGRADE

CVE-2023-31172 is a medium-severity flaw (CVSS 5.9) affecting sel-5030 acselerator quickset. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

An Incomplete Filtering of Special Elements vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0.

Why this priority

  • No elevated risk signals yet

A fixed release or distro patch exists.

Risk facts

CVSS score5.9 (Medium)
Attack vectorLocal
Attack complexityLow
Privileges neededLow
User interactionRequired
EPSS exploit chance0.3% (top 72%)
CISA exploited listNo
WeaknessCWE-791
Published2023-08-31
Last modified2026-06-17
Publisher (CNA): Schweitzer Engineering Laboratories, Inc. · Vendor: selinc

Share: LinkedIn · X · Reddit

Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

selinc sel-5030 acselerator quickset UPGRADE
Affected: <= 7.1.3.0
Fixed in: newer than 7.1.3.0
Safe to downgrade to: no unaffected older release
1. Check installed version
apt-cache policy sel-5030-acselerator-quickset || rpm -q sel-5030-acselerator-quickset || sel-5030-acselerator-quickset --version
2. UPGRADE to newer than 7.1.3.0 (Debian / Ubuntu)
sudo apt update && sudo apt install --only-upgrade sel-5030-acselerator-quickset
2. UPGRADE (RHEL / Amazon Linux / Fedora)
sudo dnf upgrade sel-5030-acselerator-quickset
Note
Distros often backport fixes without changing the version number. Confirm with the distro advisory or changelog.
Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2023-31172?

sel-5030 acselerator quickset: upgrade to newer than 7.1.3.0. Exact commands for each OS are on this page.

Is CVE-2023-31172 being exploited?

CVE-2023-31172 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2023-31172 affect?

CVE-2023-31172 affects sel-5030 acselerator quickset. Severity is medium (CVSS 5.9). An Incomplete Filtering of Special Elements vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operat

How urgent is CVE-2023-31172?

Priority 28/100. No elevated risk signals yet.