Free and open · new CVEs checked every 20 minutesStatusRSSOpen dataContact

CVE-2023-36669: Missing Authentication for a Critical Function within the Kratos NGC Indoor Unit (IDU) before 11.4 allows remo

54
This month
CRITICAL 9.8REMOTEUPGRADE

CVE-2023-36669 is a critical-severity flaw (CVSS 9.8) affecting ngc indoor unit firmware. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

Missing Authentication for a Critical Function within the Kratos NGC Indoor Unit (IDU) before 11.4 allows remote attackers to obtain arbitrary control of the IDU/ODU system. Any attacker with layer-3 network access to the IDU can impersonate the Touch Panel Unit (TPU) within the IDU by sending crafted TCP requests to the IDU.

Why this priority

  • Critical severity
  • Remotely exploitable, no login, no user action

A fixed release or distro patch exists.

Risk facts

CVSS score9.8 (Critical)
Attack vectorNetwork (remote)
Attack complexityLow
Privileges neededNone
User interactionNone
EPSS exploit chance0.9% (top 41%)
CISA exploited listNo
WeaknessCWE-306
Published2023-07-18
Last modified2026-06-17
Publisher (CNA): MITRE · Vendor: kratosdefense

Share: LinkedIn · X · Reddit

Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

kratosdefense ngc indoor unit firmware UPGRADE
Affected: < 11.4
Fixed in: 11.4
Safe to downgrade to: no unaffected older release
Check your OS release
cat /etc/os-release; uname -r
Debian / Ubuntu
sudo apt update && sudo apt full-upgrade
RHEL / Amazon Linux / Fedora
sudo dnf upgrade --refresh
Windows
Install the latest cumulative update from Windows Update
If no patch exists yet
OS downgrades are not safe. Apply the vendor mitigation from the advisory and restrict exposure.
Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2023-36669?

ngc indoor unit firmware: upgrade to 11.4. Exact commands for each OS are on this page.

Is CVE-2023-36669 being exploited?

CVE-2023-36669 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2023-36669 affect?

CVE-2023-36669 affects ngc indoor unit firmware. Severity is critical (CVSS 9.8). Missing Authentication for a Critical Function within the Kratos NGC Indoor Unit (IDU) before 11.4 allows remote attackers to obtain arbitrary control of the IDU/ODU system. Any attacker with layer-3 network access to the IDU can impersonat

How urgent is CVE-2023-36669?

Priority 54/100. Critical severity; Remotely exploitable, no login, no user action

Related CVEs

References

← Back to latest CVEs

Get the weekly exploited-CVE digest by emailThe CVEs being attacked this week and how to fix them. No spam, unsubscribe any time.