Free and open · new CVEs checked every 20 minutesStatusRSSOpen dataContact

CVE-2024-0770: A vulnerability, which was classified as critical, was found in European Chemicals Agency IUCLID 7.10.3 on Win

25
Routine
MEDIUM 4.4DOWNGRADE

CVE-2024-0770 is a medium-severity flaw (CVSS 4.4) affecting iuclid. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

A vulnerability, which was classified as critical, was found in European Chemicals Agency IUCLID 7.10.3 on Windows. Affected is an unknown function of the file iuclid6.exe of the component Desktop Installer. The manipulation leads to incorrect default permissions. The attack needs to be approached locally. VDB-251670 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in

Why this priority

  • Public exploit reference

No fix is published yet: follow the downgrade or mitigation steps.

Risk facts

CVSS score4.4 (Medium)
Attack vectorLocal
Attack complexityLow
Privileges neededLow
User interactionNone
EPSS exploit chance0.3% (top 80%)
CISA exploited listNo
WeaknessCWE-276
Published2024-01-21
Last modified2026-06-17
Publisher (CNA): VulDB · Vendor: echa.europa

Share: LinkedIn · X · Reddit

Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

echa.europa iuclid DOWNGRADE
Affected: 7.10.3
Fixed in: no fixed release known
Safe to downgrade to: a release before 7.10.3
1. Check installed version
apt-cache policy iuclid || rpm -q iuclid || iuclid --version
2. No fixed release: DOWNGRADE to a release before 7.10.3 (Debian / Ubuntu)
apt-cache madison iuclid sudo apt install iuclid=<VERSION_BEFORE_7.10.3> sudo apt-mark hold iuclid
2. No fixed release: DOWNGRADE (RHEL / Amazon Linux / Fedora)
dnf --showduplicates list iuclid sudo dnf downgrade iuclid-<VERSION_BEFORE_7.10.3> sudo dnf versionlock add iuclid
Downgrade risk
Downgrading can break dependent software and may reopen older bugs. Read the distro advisory first and test on a non-production host.
After downgrade
Restart the service, and keep the package held until a fixed release ships.
Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2024-0770?

iuclid: downgrade or apply the listed mitigation. Exact commands for each OS are on this page.

Is CVE-2024-0770 being exploited?

CVE-2024-0770 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2024-0770 affect?

CVE-2024-0770 affects iuclid. Severity is medium (CVSS 4.4). A vulnerability, which was classified as critical, was found in European Chemicals Agency IUCLID 7.10.3 on Windows. Affected is an unknown function of the file iuclid6.exe of the component Desktop Installer. The manipulation leads to incorr

How urgent is CVE-2024-0770?

Priority 25/100. Public exploit reference

Software pages

Windows vulnerabilities

Related CVEs

References

← Back to latest CVEs

Get the weekly exploited-CVE digest by emailThe CVEs being attacked this week and how to fix them. No spam, unsubscribe any time.