CVE-2024-21794: In Rapid Software LLC's Rapid SCADA versions prior to Version 5.8.4, an attacker can redirect users to malicio
CVE-2024-21794 is a medium-severity flaw (CVSS 5.4) affecting rapid scada. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.
In Rapid Software LLC's Rapid SCADA versions prior to Version 5.8.4, an attacker can redirect users to malicious pages through the login page.
Why this priority
- No elevated risk signals yet
A fixed release or distro patch exists.
Risk facts
| CVSS score | 5.4 (Medium) |
| Attack vector | Network (remote) |
| Attack complexity | Low |
| Privileges needed | Low |
| User interaction | Required |
| EPSS exploit chance | 0.3% (top 76%) |
| CISA exploited list | No |
| Weakness | CWE-601 |
| Published | 2024-02-02 |
| Last modified | 2026-06-17 |
Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score
Am I affected?
Timeline
- Published CVE record published
- Updated Record last modified
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.
Quick answers
How do I fix CVE-2024-21794?
rapid scada: upgrade to newer than 5.8.4. Exact commands for each OS are on this page.
Is CVE-2024-21794 being exploited?
CVE-2024-21794 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.
What does CVE-2024-21794 affect?
CVE-2024-21794 affects rapid scada. Severity is medium (CVSS 5.4). In Rapid Software LLC's Rapid SCADA versions prior to Version 5.8.4, an attacker can redirect users to malicious pages through the login page.
How urgent is CVE-2024-21794?
Priority 25/100. No elevated risk signals yet.
Related CVEs
- CVE-2024-47221 HIGH 7.5 UPGRADE CheckUser in ScadaServerEngine/MainLogic.cs in Rapid SCADA through 5.8.4 allows an empty password.
- CVE-2024-22096 MEDIUM 6.5 UPGRADE In Rapid Software LLC's Rapid SCADA versions prior to Version 5.8.4, an attacker can append path traversal cha
- CVE-2024-22016 HIGH 7.8 UPGRADE In Rapid Software LLC's Rapid SCADA versions prior to Version 5.8.4, an authorized user can write directly to
- CVE-2024-21869 MEDIUM 6.2 UPGRADE In Rapid Software LLC's Rapid SCADA versions prior to Version 5.8.4, the affected product stores plaintext cre
- CVE-2024-21866 MEDIUM 5.3 UPGRADE In Rapid Software LLC's Rapid SCADA versions prior to Version 5.8.4, the affected product responds back with a