Free and open · new CVEs checked every 20 minutesStatusRSSOpen dataContact

CVE-2024-2413: Intumit SmartRobot uses a fixed encryption key for authentication

51
This month
CRITICAL 9.8REMOTEUPGRADE

CVE-2024-2413 is a critical-severity flaw (CVSS 9.8) affecting smartrobot. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

Intumit SmartRobot uses a fixed encryption key for authentication. Remote attackers can use this key to encrypt a string composed of the user's name and timestamp to generate an authentication code. With this authentication code, they can obtain administrator privileges and subsequently execute arbitrary code on the remote server using built-in system functionality.

Why this priority

  • Critical severity
  • Remotely exploitable, no login, no user action

A fixed release or distro patch exists.

Risk facts

CVSS score9.8 (Critical)
Attack vectorNetwork (remote)
Attack complexityLow
Privileges neededNone
User interactionNone
EPSS exploit chance0.6% (top 53%)
CISA exploited listNo
WeaknessCWE-321
Published2024-03-13
Last modified2026-06-17
Publisher (CNA): TWCERT/CC · Vendor: intumit

Share: LinkedIn · X · Reddit

Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

intumit smartrobot UPGRADE
Affected: < 6.2.0-202303TW
Fixed in: 6.2.0-202303TW
Safe to downgrade to: no unaffected older release
1. Check installed version
apt-cache policy smartrobot || rpm -q smartrobot || smartrobot --version
2. UPGRADE to 6.2.0-202303TW (Debian / Ubuntu)
sudo apt update && sudo apt install --only-upgrade smartrobot
2. UPGRADE (RHEL / Amazon Linux / Fedora)
sudo dnf upgrade smartrobot
Note
Distros often backport fixes without changing the version number. Confirm with the distro advisory or changelog.
Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2024-2413?

smartrobot: upgrade to 6.2.0-202303TW. Exact commands for each OS are on this page.

Is CVE-2024-2413 being exploited?

CVE-2024-2413 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2024-2413 affect?

CVE-2024-2413 affects smartrobot. Severity is critical (CVSS 9.8). Intumit SmartRobot uses a fixed encryption key for authentication. Remote attackers can use this key to encrypt a string composed of the user's name and timestamp to generate an authentication code. With this authentication code, they can o

How urgent is CVE-2024-2413?

Priority 51/100. Critical severity; Remotely exploitable, no login, no user action

Related CVEs

References

← Back to latest CVEs

Get the weekly exploited-CVE digest by emailThe CVEs being attacked this week and how to fix them. No spam, unsubscribe any time.