Free and open · new CVEs checked every 20 minutesStatusRSSOpen dataContact

CVE-2024-33606: An attacker could retrieve sensitive files (medical images) as well as plant new medical images or overwrite e

41
This month
HIGH 8.8UPGRADE

CVE-2024-33606 is a high-severity flaw (CVSS 8.8) affecting dicom viewer. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

An attacker could retrieve sensitive files (medical images) as well as plant new medical images or overwrite existing medical images on a MicroDicom DICOM Viewer system. User interaction is required to exploit this vulnerability.

Why this priority

  • High severity

A fixed release or distro patch exists.

Risk facts

CVSS score8.8 (High)
Attack vectorNetwork (remote)
Attack complexityLow
Privileges neededNone
User interactionRequired
EPSS exploit chance0.5% (top 60%)
CISA exploited listNo
WeaknessCWE-939, CWE-862
Published2024-06-11
Last modified2026-06-17
Publisher (CNA): ICS-CERT · Vendor: microdicom

Share: LinkedIn · X · Reddit

Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

microdicom dicom viewer UPGRADE
Affected: < 2024.2
Fixed in: 2024.2
Safe to downgrade to: no unaffected older release
1. Check installed version
apt-cache policy dicom-viewer || rpm -q dicom-viewer || dicom-viewer --version
2. UPGRADE to 2024.2 (Debian / Ubuntu)
sudo apt update && sudo apt install --only-upgrade dicom-viewer
2. UPGRADE (RHEL / Amazon Linux / Fedora)
sudo dnf upgrade dicom-viewer
Note
Distros often backport fixes without changing the version number. Confirm with the distro advisory or changelog.
Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2024-33606?

dicom viewer: upgrade to 2024.2. Exact commands for each OS are on this page.

Is CVE-2024-33606 being exploited?

CVE-2024-33606 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2024-33606 affect?

CVE-2024-33606 affects dicom viewer. Severity is high (CVSS 8.8). An attacker could retrieve sensitive files (medical images) as well as plant new medical images or overwrite existing medical images on a MicroDicom DICOM Viewer system. User interaction is required to exploit this vulnerability.

How urgent is CVE-2024-33606?

Priority 41/100. High severity

Related CVEs

References

← Back to latest CVEs

Get the weekly exploited-CVE digest by emailThe CVEs being attacked this week and how to fix them. No spam, unsubscribe any time.