CVE-2024-45763: Dell Enterprise SONiC OS, version(s) 4.1.x, 4.2.x, contain(s) an Improper Neutralization of Special Elements u
CVE-2024-45763 is a critical-severity flaw (CVSS 9.1) affecting enterprise sonic distribution. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.
Dell Enterprise SONiC OS, version(s) 4.1.x, 4.2.x, contain(s) an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Command execution. This is a critical severity vulnerability so Dell recommends customers to upgrade at the earliest opportunity.
Why this priority
- Critical severity
A fixed release or distro patch exists.
Risk facts
| CVSS score | 9.1 (Critical) |
| Attack vector | Network (remote) |
| Attack complexity | Low |
| Privileges needed | High |
| User interaction | None |
| EPSS exploit chance | 1.4% (top 28%) |
| CISA exploited list | No |
| Weakness | CWE-78 |
| Published | 2024-11-08 |
| Last modified | 2026-06-17 |
Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score
Am I affected?
Timeline
- Published CVE record published
- Updated Record last modified
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.
Quick answers
How do I fix CVE-2024-45763?
enterprise sonic distribution: upgrade to 4.1.6, 4.2.2. Exact commands for each OS are on this page.
Is CVE-2024-45763 being exploited?
CVE-2024-45763 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.
What does CVE-2024-45763 affect?
CVE-2024-45763 affects enterprise sonic distribution. Severity is critical (CVSS 9.1). Dell Enterprise SONiC OS, version(s) 4.1.x, 4.2.x, contain(s) an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A high privileged attacker with remote access could potentially explo
How urgent is CVE-2024-45763?
Priority 50/100. Critical severity
Software pages
Related CVEs
- CVE-2025-23374 HIGH 8.0 UPGRADE Dell Networking Switches running Enterprise SONiC OS, version(s) prior to 4.4.1 and 4.2.3, contain(s) an Inser
- CVE-2024-45765 CRITICAL 9.1 UPGRADE Dell Enterprise SONiC OS, version(s) 4.1.x, 4.2.x, contain(s) an Improper Neutralization of Special Elements u
- CVE-2024-45764 CRITICAL 9.0 UPGRADE Dell Enterprise SONiC OS, version(s) 4.1.x, 4.2.x, contain(s) a Missing Critical Step in Authentication vulner