Free and open · new CVEs checked every 20 minutesStatusRSSOpen dataContact

CVE-2024-46327: An issue in the Http_handle object of VONETS VAP11G-300 v3.3.23.6.9 allows attackers to access sensitive files

27
Routine
MEDIUM 5.7MITIGATE

CVE-2024-46327 is a medium-severity flaw (CVSS 5.7) affecting vap11g-300 firmware. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

An issue in the Http_handle object of VONETS VAP11G-300 v3.3.23.6.9 allows attackers to access sensitive files via a directory traversal.

Why this priority

  • No elevated risk signals yet

No fix is published yet: follow the downgrade or mitigation steps.

Risk facts

CVSS score5.7 (Medium)
Attack vectorAdjacent network
Attack complexityLow
Privileges neededLow
User interactionNone
EPSS exploit chance0.4% (top 70%)
CISA exploited listNo
WeaknessCWE-22
Published2024-09-26
Last modified2026-06-17
Publisher (CNA): MITRE · Vendor: vonets

Share: LinkedIn · X · Reddit

Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

vonets vap11g-300 firmware MITIGATE
Affected: 3.3.23.6.9
Fixed in: no fixed release known
Safe to downgrade to: a release before 3.3.23.6.9
Check your OS release
cat /etc/os-release; uname -r
Debian / Ubuntu
sudo apt update && sudo apt full-upgrade
RHEL / Amazon Linux / Fedora
sudo dnf upgrade --refresh
Windows
Install the latest cumulative update from Windows Update
If no patch exists yet
OS downgrades are not safe. Apply the vendor mitigation from the advisory and restrict exposure.
Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2024-46327?

vap11g-300 firmware: mitigate or apply the listed mitigation. Exact commands for each OS are on this page.

Is CVE-2024-46327 being exploited?

CVE-2024-46327 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2024-46327 affect?

CVE-2024-46327 affects vap11g-300 firmware. Severity is medium (CVSS 5.7). An issue in the Http_handle object of VONETS VAP11G-300 v3.3.23.6.9 allows attackers to access sensitive files via a directory traversal.

How urgent is CVE-2024-46327?

Priority 27/100. No elevated risk signals yet.