Free and open · new CVEs checked every 20 minutesStatusRSSOpen dataContact

CVE-2024-7016: Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in S

25
Routine
MEDIUM 4.8UPGRADE

CVE-2024-7016 is a medium-severity flaw (CVSS 4.8) affecting smart doctor. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Smarttek Informatics Smart Doctor's allows Stored XSS required admin privileges. This issue affects Smart Doctor: through 21.11.2024. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Why this priority

  • No elevated risk signals yet

A fixed release or distro patch exists.

Risk facts

CVSS score4.8 (Medium)
Attack vectorNetwork (remote)
Attack complexityLow
Privileges neededHigh
User interactionRequired
EPSS exploit chance0.4% (top 67%)
CISA exploited listNo
WeaknessCWE-79
Published2024-11-21
Last modified2026-06-17
Publisher (CNA): Computer Emergency Response Team of the Republic of Turkey · Vendor: smarttek

Share: LinkedIn · X · Reddit

Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

smarttek smart doctor UPGRADE
Affected: <= 2024-11-21
Fixed in: newer than 2024-11-21
Safe to downgrade to: no unaffected older release
1. Check installed version
apt-cache policy smart-doctor || rpm -q smart-doctor || smart-doctor --version
2. UPGRADE to newer than 2024-11-21 (Debian / Ubuntu)
sudo apt update && sudo apt install --only-upgrade smart-doctor
2. UPGRADE (RHEL / Amazon Linux / Fedora)
sudo dnf upgrade smart-doctor
Note
Distros often backport fixes without changing the version number. Confirm with the distro advisory or changelog.
Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2024-7016?

smart doctor: upgrade to newer than 2024-11-21. Exact commands for each OS are on this page.

Is CVE-2024-7016 being exploited?

CVE-2024-7016 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2024-7016 affect?

CVE-2024-7016 affects smart doctor. Severity is medium (CVSS 4.8). Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Smarttek Informatics Smart Doctor's allows Stored XSS required admin privileges. This issue affects Smart Doctor: through 21.11.20

How urgent is CVE-2024-7016?

Priority 25/100. No elevated risk signals yet.

References

← Back to latest CVEs

Get the weekly exploited-CVE digest by emailThe CVEs being attacked this week and how to fix them. No spam, unsubscribe any time.