Free and open · new CVEs checked every 20 minutesStatusRSSOpen dataContact

CVE-2024-7613: A vulnerability was found in Tenda FH1206 1.2.0.8(8155) and classified as critical

54
This month
HIGH 8.8MITIGATE

CVE-2024-7613 is a high-severity flaw (CVSS 8.8) affecting fh1206 firmware. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

A vulnerability was found in Tenda FH1206 1.2.0.8(8155) and classified as critical. This issue affects the function fromGstDhcpSetSer of the file /goform/GstDhcpSetSer. The manipulation of the argument dips leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Why this priority

  • High severity
  • Public exploit reference

No fix is published yet: follow the downgrade or mitigation steps.

Risk facts

CVSS score8.8 (High)
Attack vectorNetwork (remote)
Attack complexityLow
Privileges neededLow
User interactionNone
EPSS exploit chance1.5% (top 26%)
CISA exploited listNo
WeaknessCWE-120, CWE-787
Published2024-08-12
Last modified2026-06-17
Publisher (CNA): VulDB · Vendor: tenda

Share: LinkedIn · X · Reddit

Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

tenda fh1206 firmware MITIGATE
Affected: 1.2.0.8\(8155\)
Fixed in: no fixed release known
Safe to downgrade to: no unaffected older release
Check your OS release
cat /etc/os-release; uname -r
Debian / Ubuntu
sudo apt update && sudo apt full-upgrade
RHEL / Amazon Linux / Fedora
sudo dnf upgrade --refresh
Windows
Install the latest cumulative update from Windows Update
If no patch exists yet
OS downgrades are not safe. Apply the vendor mitigation from the advisory and restrict exposure.
Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2024-7613?

fh1206 firmware: mitigate or apply the listed mitigation. Exact commands for each OS are on this page.

Is CVE-2024-7613 being exploited?

CVE-2024-7613 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2024-7613 affect?

CVE-2024-7613 affects fh1206 firmware. Severity is high (CVSS 8.8). A vulnerability was found in Tenda FH1206 1.2.0.8(8155) and classified as critical. This issue affects the function fromGstDhcpSetSer of the file /goform/GstDhcpSetSer. The manipulation of the argument dips leads to buffer overflow. The att

How urgent is CVE-2024-7613?

Priority 54/100. High severity; Public exploit reference

Related CVEs

References

← Back to latest CVEs

Get the weekly exploited-CVE digest by emailThe CVEs being attacked this week and how to fix them. No spam, unsubscribe any time.