Free and open · new CVEs checked every 20 minutesStatusRSSOpen dataContact

CVE-2024-7731: Dr.ID Access Control System from SECOM does not properly validate a specific page parameter, allowing unauthen

54
This month
CRITICAL 9.8REMOTEUPGRADE

CVE-2024-7731 is a critical-severity flaw (CVSS 9.8) affecting dr.id access control. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

Dr.ID Access Control System from SECOM does not properly validate a specific page parameter, allowing unauthenticated remote attackers to inject SQL commands to read, modify, and delete database contents.

Why this priority

  • Critical severity
  • Remotely exploitable, no login, no user action

A fixed release or distro patch exists.

Risk facts

CVSS score9.8 (Critical)
Attack vectorNetwork (remote)
Attack complexityLow
Privileges neededNone
User interactionNone
EPSS exploit chance0.8% (top 42%)
CISA exploited listNo
WeaknessCWE-89
Published2024-08-14
Last modified2026-06-17
Publisher (CNA): TWCERT/CC · Vendor: secom

Share: LinkedIn · X · Reddit

Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

secom dr.id access control UPGRADE
Affected: < 3.6.3
Fixed in: 3.6.3
Safe to downgrade to: no unaffected older release
1. Check installed version
apt-cache policy dr.id-access-control || rpm -q dr.id-access-control || dr.id-access-control --version
2. UPGRADE to 3.6.3 (Debian / Ubuntu)
sudo apt update && sudo apt install --only-upgrade dr.id-access-control
2. UPGRADE (RHEL / Amazon Linux / Fedora)
sudo dnf upgrade dr.id-access-control
Note
Distros often backport fixes without changing the version number. Confirm with the distro advisory or changelog.
Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2024-7731?

dr.id access control: upgrade to 3.6.3. Exact commands for each OS are on this page.

Is CVE-2024-7731 being exploited?

CVE-2024-7731 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2024-7731 affect?

CVE-2024-7731 affects dr.id access control. Severity is critical (CVSS 9.8). Dr.ID Access Control System from SECOM does not properly validate a specific page parameter, allowing unauthenticated remote attackers to inject SQL commands to read, modify, and delete database contents.

How urgent is CVE-2024-7731?

Priority 54/100. Critical severity; Remotely exploitable, no login, no user action

References

← Back to latest CVEs

Get the weekly exploited-CVE digest by emailThe CVEs being attacked this week and how to fix them. No spam, unsubscribe any time.