CVE-2024-8225: A vulnerability, which was classified as critical, was found in Tenda G3 15.11.0.20
CVE-2024-8225 is a high-severity flaw (CVSS 8.8) affecting g3 firmware. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.
A vulnerability, which was classified as critical, was found in Tenda G3 15.11.0.20. Affected is the function formSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument sysTimePolicy leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Why this priority
- High severity
- Public exploit reference
No fix is published yet: follow the downgrade or mitigation steps.
Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score
Am I affected?
Timeline
- Published CVE record published
- Updated Record last modified
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.
Quick answers
How do I fix CVE-2024-8225?
g3 firmware: mitigate or apply the listed mitigation. Exact commands for each OS are on this page.
Is CVE-2024-8225 being exploited?
CVE-2024-8225 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.
What does CVE-2024-8225 affect?
CVE-2024-8225 affects g3 firmware. Severity is high (CVSS 8.8). A vulnerability, which was classified as critical, was found in Tenda G3 15.11.0.20. Affected is the function formSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument sysTimePolicy leads to stack-based buffer overf
How urgent is CVE-2024-8225?
Priority 53/100. High severity; Public exploit reference
Related CVEs
- CVE-2025-57078 HIGH 7.5 UPGRADE Tenda G3 v3.0br_V15.11.0.17 was discovered to contain a stack overflow in the pppoeServerWhiteMacIndex paramet
- CVE-2025-57072 HIGH 7.5 MITIGATE Tenda G3 v3.0br_V15.11.0.17 was discovered to contain a stack overflow in the staticRouteGateway parameter in
- CVE-2025-57071 HIGH 7.5 MITIGATE Tenda G3 v3.0br_V15.11.0.17 was discovered to contain a stack overflow in the vpnUsers parameter in the formAd
- CVE-2025-57070 HIGH 7.5 MITIGATE Tenda G3 v3.0br_V15.11.0.17 was discovered to contain a stack overflow in the gstUp parameter in the guestWifi
- CVE-2025-57069 HIGH 7.5 MITIGATE Tenda G3 v3.0br_V15.11.0.17 was discovered to contain a stack overflow in the pPppUser parameter in the getsin