CVE-2025-0497: A data exposure vulnerability exists in all versions prior to V15.00.001 of Rockwell Automation FactoryTalk® A
CVE-2025-0497 is a critical-severity flaw (CVSS 9.8) affecting factorytalk assetcentre. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.
A data exposure vulnerability exists in all versions prior to V15.00.001 of Rockwell Automation FactoryTalk® AssetCentre. The vulnerability exists due to storing credentials in the configuration file of EventLogAttachmentExtractor, ArchiveExtractor, LogCleanUp, or ArchiveLogCleanUp packages.
Why this priority
- Critical severity
- Remotely exploitable, no login, no user action
A fixed release or distro patch exists.
Risk facts
| CVSS score | 9.8 (Critical) |
| Attack vector | Network (remote) |
| Attack complexity | Low |
| Privileges needed | None |
| User interaction | None |
| EPSS exploit chance | 0.3% (top 74%) |
| CISA exploited list | No |
| Weakness | CWE-522 |
| Published | 2025-01-30 |
| Last modified | 2026-06-17 |
Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score
Am I affected?
Timeline
- Published CVE record published
- Updated Record last modified
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.
Quick answers
How do I fix CVE-2025-0497?
factorytalk assetcentre: upgrade to 15.00.01. Exact commands for each OS are on this page.
Is CVE-2025-0497 being exploited?
CVE-2025-0497 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.
What does CVE-2025-0497 affect?
CVE-2025-0497 affects factorytalk assetcentre. Severity is critical (CVSS 9.8). A data exposure vulnerability exists in all versions prior to V15.00.001 of Rockwell Automation FactoryTalk® AssetCentre. The vulnerability exists due to storing credentials in the configuration file of EventLogAttachmentExtractor, ArchiveE
How urgent is CVE-2025-0497?
Priority 46/100. Critical severity; Remotely exploitable, no login, no user action
Software pages
Rockwell Automation vulnerabilities
Related CVEs
- CVE-2025-0498 CRITICAL 9.8 UPGRADE A data exposure vulnerability exists in all versions prior to V15.00.001 of Rockwell Automation FactoryTalk® A
- CVE-2025-0477 CRITICAL 9.8 UPGRADE An encryption vulnerability exists in all versions prior to V15.00.001 of Rockwell Automation FactoryTalk® Ass