Free and open · new CVEs checked every 20 minutesStatusRSSOpen dataContact

CVE-2025-11104: A vulnerability was detected in CodeAstro Electricity Billing System 1.0

34
Routine
MEDIUM 6.3DOWNGRADE

CVE-2025-11104 is a medium-severity flaw (CVSS 6.3) affecting electricity billing system. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

A vulnerability was detected in CodeAstro Electricity Billing System 1.0. Affected by this issue is some unknown functionality of the file /admin/bill.php. The manipulation of the argument uid results in sql injection. The attack may be launched remotely. The exploit is now public and may be used.

Why this priority

  • Public exploit reference

No fix is published yet: follow the downgrade or mitigation steps.

Risk facts

CVSS score6.3 (Medium)
Attack vectorNetwork (remote)
Attack complexityLow
Privileges neededLow
User interactionNone
EPSS exploit chance0.3% (top 72%)
CISA exploited listNo
WeaknessCWE-74, CWE-89
Published2025-09-28
Last modified2026-10-09
Publisher (CNA): VulDB · Vendor: codeastro

Share: LinkedIn · X · Reddit

Last updated 2026-10-09 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

codeastro electricity billing system DOWNGRADE
Affected: 1.0
Fixed in: no fixed release known
Safe to downgrade to: a release before 1.0
1. Check installed version
apt-cache policy electricity-billing-system || rpm -q electricity-billing-system || electricity-billing-system --version
2. No fixed release: DOWNGRADE to a release before 1.0 (Debian / Ubuntu)
apt-cache madison electricity-billing-system sudo apt install electricity-billing-system=<VERSION_BEFORE_1.0> sudo apt-mark hold electricity-billing-system
2. No fixed release: DOWNGRADE (RHEL / Amazon Linux / Fedora)
dnf --showduplicates list electricity-billing-system sudo dnf downgrade electricity-billing-system-<VERSION_BEFORE_1.0> sudo dnf versionlock add electricity-billing-system
Downgrade risk
Downgrading can break dependent software and may reopen older bugs. Read the distro advisory first and test on a non-production host.
After downgrade
Restart the service, and keep the package held until a fixed release ships.
Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2025-11104?

electricity billing system: downgrade or apply the listed mitigation. Exact commands for each OS are on this page.

Is CVE-2025-11104 being exploited?

CVE-2025-11104 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2025-11104 affect?

CVE-2025-11104 affects electricity billing system. Severity is medium (CVSS 6.3). A vulnerability was detected in CodeAstro Electricity Billing System 1.0. Affected by this issue is some unknown functionality of the file /admin/bill.php. The manipulation of the argument uid results in sql injection. The attack may be lau

How urgent is CVE-2025-11104?

Priority 34/100. Public exploit reference

Software pages

PHP vulnerabilities

Related CVEs

References

← Back to latest CVEs

Get the weekly exploited-CVE digest by emailThe CVEs being attacked this week and how to fix them. No spam, unsubscribe any time.