CVE-2025-12995: Medtronic CareLink Network allows an unauthenticated remote attacker to perform a brute force attack on an API
CVE-2025-12995 is a high-severity flaw (CVSS 8.1) affecting carelink network. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.
Medtronic CareLink Network allows an unauthenticated remote attacker to perform a brute force attack on an API endpoint that could be used to determine a valid password under certain circumstances. This issue affects CareLink Network: before December 4, 2025.
Why this priority
- High severity
- Remotely exploitable, no login, no user action
A fixed release or distro patch exists.
Risk facts
| CVSS score | 8.1 (High) |
| Attack vector | Network (remote) |
| Attack complexity | High |
| Privileges needed | None |
| User interaction | None |
| EPSS exploit chance | 0.3% (top 73%) |
| CISA exploited list | No |
| Weakness | CWE-307 |
| Published | 2025-12-04 |
| Last modified | 2026-09-25 |
Last updated 2026-09-25 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score
Am I affected?
Timeline
- Published CVE record published
- Updated Record last modified
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.
Quick answers
How do I fix CVE-2025-12995?
carelink network: upgrade to 2025-12-04. Exact commands for each OS are on this page.
Is CVE-2025-12995 being exploited?
CVE-2025-12995 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.
What does CVE-2025-12995 affect?
CVE-2025-12995 affects carelink network. Severity is high (CVSS 8.1). Medtronic CareLink Network allows an unauthenticated remote attacker to perform a brute force attack on an API endpoint that could be used to determine a valid password under certain circumstances. This issue affects CareLink Network: befor
How urgent is CVE-2025-12995?
Priority 40/100. High severity; Remotely exploitable, no login, no user action
Related CVEs
- CVE-2025-12994 MEDIUM 5.3 UPGRADE Medtronic CareLink Network allows an unauthenticated remote attacker to initiate a request for security questi
- CVE-2025-12996 MEDIUM 4.1 UPGRADE Medtronic CareLink Network allows a local attacker with access to log files on an internal API server to view
- CVE-2025-12997 LOW 2.2 UPGRADE Insecure Direct Object Reference vulnerability in Medtronic CareLink Network which allows an authenticated att