Free and open · new CVEs checked every 20 minutesStatusRSSOpen dataContact

CVE-2025-27654: Vasion Print (formerly PrinterLogic) before Virtual Appliance Host 22.0.862 Application 20.0.2014 allows Cross

32
Routine
MEDIUM 6.1UPGRADEUPGRADE

CVE-2025-27654 is a medium-severity flaw (CVSS 6.1) affecting vasion print, virtual appliance. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.

Vasion Print (formerly PrinterLogic) before Virtual Appliance Host 22.0.862 Application 20.0.2014 allows Cross Site Scripting (XSS) V-2023-017.

Why this priority

  • No elevated risk signals yet

A fixed release or distro patch exists.

Risk facts

CVSS score6.1 (Medium)
Attack vectorNetwork (remote)
Attack complexityLow
Privileges neededNone
User interactionRequired
EPSS exploit chance0.5% (top 56%)
CISA exploited listNo
WeaknessCWE-79
Published2025-03-05
Last modified2026-06-17
Publisher (CNA): MITRE · Vendor: printerlogic

Share: LinkedIn · X · Reddit

Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score

Am I affected?

Timeline

printerlogic vasion print UPGRADE
Affected: < 20.0.2014
Fixed in: 20.0.2014
Safe to downgrade to: no unaffected older release
1. Check installed version
apt-cache policy vasion-print || rpm -q vasion-print || vasion-print --version
2. UPGRADE to 20.0.2014 (Debian / Ubuntu)
sudo apt update && sudo apt install --only-upgrade vasion-print
2. UPGRADE (RHEL / Amazon Linux / Fedora)
sudo dnf upgrade vasion-print
Note
Distros often backport fixes without changing the version number. Confirm with the distro advisory or changelog.
printerlogic virtual appliance UPGRADE
Affected: < 22.0.862
Fixed in: 22.0.862
Safe to downgrade to: no unaffected older release
1. Check installed version
apt-cache policy virtual-appliance || rpm -q virtual-appliance || virtual-appliance --version
2. UPGRADE to 22.0.862 (Debian / Ubuntu)
sudo apt update && sudo apt install --only-upgrade virtual-appliance
2. UPGRADE (RHEL / Amazon Linux / Fedora)
sudo dnf upgrade virtual-appliance
Note
Distros often backport fixes without changing the version number. Confirm with the distro advisory or changelog.
Verify at the official source NVD · CVE Program · Report a problem with this page
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.

Quick answers

How do I fix CVE-2025-27654?

vasion print: upgrade to 20.0.2014; virtual appliance: upgrade to 22.0.862. Exact commands for each OS are on this page.

Is CVE-2025-27654 being exploited?

CVE-2025-27654 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.

What does CVE-2025-27654 affect?

CVE-2025-27654 affects vasion print, virtual appliance. Severity is medium (CVSS 6.1). Vasion Print (formerly PrinterLogic) before Virtual Appliance Host 22.0.862 Application 20.0.2014 allows Cross Site Scripting (XSS) V-2023-017.

How urgent is CVE-2025-27654?

Priority 32/100. No elevated risk signals yet.

Related CVEs

References

← Back to latest CVEs

Get the weekly exploited-CVE digest by emailThe CVEs being attacked this week and how to fix them. No spam, unsubscribe any time.