CVE-2025-27654: Vasion Print (formerly PrinterLogic) before Virtual Appliance Host 22.0.862 Application 20.0.2014 allows Cross
CVE-2025-27654 is a medium-severity flaw (CVSS 6.1) affecting vasion print, virtual appliance. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.
Vasion Print (formerly PrinterLogic) before Virtual Appliance Host 22.0.862 Application 20.0.2014 allows Cross Site Scripting (XSS) V-2023-017.
Why this priority
- No elevated risk signals yet
A fixed release or distro patch exists.
Risk facts
| CVSS score | 6.1 (Medium) |
| Attack vector | Network (remote) |
| Attack complexity | Low |
| Privileges needed | None |
| User interaction | Required |
| EPSS exploit chance | 0.5% (top 56%) |
| CISA exploited list | No |
| Weakness | CWE-79 |
| Published | 2025-03-05 |
| Last modified | 2026-06-17 |
Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score
Am I affected?
Timeline
- Published CVE record published
- Updated Record last modified
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.
Quick answers
How do I fix CVE-2025-27654?
vasion print: upgrade to 20.0.2014; virtual appliance: upgrade to 22.0.862. Exact commands for each OS are on this page.
Is CVE-2025-27654 being exploited?
CVE-2025-27654 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.
What does CVE-2025-27654 affect?
CVE-2025-27654 affects vasion print, virtual appliance. Severity is medium (CVSS 6.1). Vasion Print (formerly PrinterLogic) before Virtual Appliance Host 22.0.862 Application 20.0.2014 allows Cross Site Scripting (XSS) V-2023-017.
How urgent is CVE-2025-27654?
Priority 32/100. No elevated risk signals yet.
Related CVEs
- CVE-2025-27685 HIGH 7.5 UPGRADE UPGRADE Vasion Print (formerly PrinterLogic) before Virtual Appliance Host 1.0.735 Application 20.0.1330 allows Config
- CVE-2025-27684 HIGH 7.5 UPGRADE UPGRADE Vasion Print (formerly PrinterLogic) before Virtual Appliance Host 1.0.735 Application 20.0.1330 allows Debug
- CVE-2025-27683 HIGH 8.8 UPGRADE UPGRADE Vasion Print (formerly PrinterLogic) before Virtual Appliance Host 1.0.735 Application 20.0.1330 allows Driver
- CVE-2025-27682 CRITICAL 9.8 UPGRADE UPGRADE Vasion Print (formerly PrinterLogic) before Virtual Appliance Host 1.0.735 Application 20.0.1330 allows Insecu
- CVE-2025-27681 CRITICAL 9.8 UPGRADE UPGRADE Vasion Print (formerly PrinterLogic) before Virtual Appliance Host 1.0.735 Application 20.0.1330 mishandles Cl