CVE-2025-28228: A credential exposure vulnerability in Electrolink 500W, 1kW, 2kW Medium DAB Transmitter Web v01.09, v01.08, v
CVE-2025-28228 is a high-severity flaw (CVSS 7.5) affecting fm\/dab\/tv transmitter web management system. Below: why it ranks where it does, which versions are affected, what to do, and the exact commands.
A credential exposure vulnerability in Electrolink 500W, 1kW, 2kW Medium DAB Transmitter Web v01.09, v01.08, v01.07, and Display v1.4, v1.2 allows unauthorized attackers to access credentials in plaintext.
Why this priority
- High severity
- Public exploit reference
- Remotely exploitable, no login, no user action
No fix is published yet: follow the downgrade or mitigation steps.
Risk facts
| CVSS score | 7.5 (High) |
| Attack vector | Network (remote) |
| Attack complexity | Low |
| Privileges needed | None |
| User interaction | None |
| EPSS exploit chance | 1.8% (top 22%) |
| CISA exploited list | No |
| Weakness | CWE-522 |
| Published | 2025-04-18 |
| Last modified | 2026-06-17 |
Last updated 2026-06-17 · Sources: CVE Program, NVD, CISA KEV, EPSS and vendor advisories · How we score
Am I affected?
Timeline
- Published CVE record published
- Updated Record last modified
Public exploits and detection
Public code exists for this CVE. Treat unpatched systems as at risk, and only run PoCs in a lab.
- Nuclei scan template: Electrolink FM/DAB/TV Transmitter - Credentials Disclosure
Scores and fixes here are computed automatically from those and other public sources. Confirm with the vendor advisory before changing production systems.
Quick answers
How do I fix CVE-2025-28228?
fm\/dab\/tv transmitter web management system: mitigate or apply the listed mitigation. Exact commands for each OS are on this page.
Is CVE-2025-28228 being exploited?
CVE-2025-28228 is not on the CISA Known Exploited Vulnerabilities list at the time of the last update. Check again, as this can change.
What does CVE-2025-28228 affect?
CVE-2025-28228 affects fm\/dab\/tv transmitter web management system. Severity is high (CVSS 7.5). A credential exposure vulnerability in Electrolink 500W, 1kW, 2kW Medium DAB Transmitter Web v01.09, v01.08, v01.07, and Display v1.4, v1.2 allows unauthorized attackers to access credentials in plaintext.
How urgent is CVE-2025-28228?
Priority 56/100. High severity; Public exploit reference; Remotely exploitable, no login, no user action
Related CVEs
- CVE-2025-51040 HIGH 7.5 DOWNGRADE Electrolink FM/DAB/TV Transmitter Web Management System Unauthorized access vulnerability via the /FrameSetCor